Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 30, 2026
I've been on Agile for about 14 months and so far no issues with metering or billing. Before I decide to switch to TE I shall ask them, in the light...
@transparent Thank you for your detailed reply. I will take a look at the consultation documents. My research today uncovered a lot of negative rev...
Thanks. But what is the downside? I have been with 2 energy companies that failed and they just get mopped up by someone else - that's how I ended u...
I assume you don't have any useable loft space for the DHW tank? We installed a Mixergy 210l in our loft when the Ecodan was installed 18 months ago ...
@greenlover75 slightly off topic but has your architect considered vacuum glazing? This fits in existing frames and has been approved for listed pro...
@toodles Yes I was on Agile last Jan and still am. Jan 2024 I used c2000kWh and Agile cost was around 50% of Flexible. Jan 2025 I used almost exac...
Yes much lower volume in the rads. So the system heats up quickly. We have a 100l buffer but I think that was in the default design anyway. You can...
Yes each Jaga needs a power supply but there is room inside the casing for the small transformer - the controller and fans use 24V DC. I installed a ...
Are you aware of Jaga Strada fan-assisted rads? We have them fitted throughout and are very happy. Heat output is much greater per unit area than no...
My 14kW Ecodan is defrosting about every 2 hours this morning. Once at 0730 and then again at 0930 (see attached). Conditions are 3C and 88% humidi...
- 27 Forums
- 2,783 Topics
- 65.6 K Posts
- 1,852 Online
- 7,187 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: How should the Boiler Upgrade Scheme be reformed?
Yes, their gas typically costs twice ours and electrici...
By Batpred , 20 minutes ago
-
Over the years, due to the non barrier PEX underfloor h...
By bobflux , 1 hour ago
-
RE: Getting closer to a finished Haier system
All the 45° elbows required for getting the primaries i...
By Singlespeed , 2 hours ago
-
RE: Tesla Powerwall (2) Calibration Cycles
@papahuhu Likewise, the main ‘extra’ relates to TOU tar...
By Toodles , 8 hours ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
That sounds like a better approach (being able to see a...
By cathodeRay , 1 day ago
-
RE: DIY Heat Pump Installations: Navigating Legal and Regulatory Hurdles
Thanks for the reference @jamespa I can't see any te...
By Transparent , 1 day ago
-
RE: battery storage without solar
Indeed, current on the grid input = current used for ch...
By bobflux , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu @papahuhu A lot of tears and sweat went into ...
By Andris , 1 day ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
We have the same problem, 12 mature trees clip the morn...
By Papahuhu , 2 days ago
-
RE: Solis inverters S6-EH1P: pros and cons and battery options
I had a battery and inverter installed a while ago, my ...
By Batpred , 2 days ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
@ltron2 The EPC on our house is A-92, however that i...
By Rob of York , 2 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
The layout is confusing - much better like this: We b...
By downfield , 4 days ago
-
RE: Is it just me, or does tradesperson timekeeping and communication drive you absolutely mad?
My experience, backed up by opinions from various frien...
By Majordennisbloodnok , 4 days ago
-
RE: Analysis of the economics of switching to an A2W ASHP compared to other heat sources
I had a meeting today with a company based out of Swede...
By Mars , 4 days ago
-
RE: Review your electricity provider
We were with Octopus in our old house and it was fault...
By ian33a , 4 days ago