Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Feb 11, 2025
What's funny is the heat pump says its only using 21kwh a day but I know our normal use is around 10, so any idea where the remaining 20kwh might be b...
You can do some ballpark maths to see if it is doing OK. E.g. if the outside temperature is -2 over a 24 hour period and your flow temperature was 4...
Cycling might happen if it is controlled by a room thermostat. The heat pump runs hard (and noisily) to get to a high +40 LWT until the room stat stop...
Yes, you would need to reduce the pressure to the correct value for your system (usually 1 to 1.5 bar when cold). And as @jamespa says, disconne...
The heat loss differs depending on the pipe diameter (and flow temperature, presumably). Here are some of the numbers I could find: 15mm 7.89 W/m22m...
Something similar happened to me once with a gas system boiler. The filling loop hadn't been closed properly and it was pushing up the pressure over t...
I guess I'm wrong about the efficiency but the sound power level of the Grant is 65 dB vs 54 dB for the Vaillant and 52 dB for the Logic. More than 10...
I'm far from an expert, @dorkypark, but my understanding is that openings like air bricks are only an issue if within 1m of the bottom of an R290 heat...
- 26 Forums
- 2,645 Topics
- 61.8 K Posts
- 548 Online
- 7,045 Members
Join Us!
Latest Posts
-
RE: Heat Pump Overpromising – What Were You Actually Told Before You Bought?
No, I agree entirely. There shouldn't be a need for an ...
By Majordennisbloodnok , 6 minutes ago
-
RE: How many people are happy with their ASHP and do you believe them?
I agree, and not. Energy prices are a largely politica...
By JamesPa , 50 minutes ago
-
RE: Solar Produced vs Home Consumed
All inverters will use solar power in preference to dra...
By JamesPa , 56 minutes ago
-
Yes, you will need to notify them even if the inverter ...
By Old_Scientist , 1 hour ago
-
RE: Heat Pump Manufacturers Recommending Buffer Tanks
@tony-stolz, I think @jamespa has already covered the h...
By Mars , 14 hours ago
-
RE: Heat Pump Operation in Summer - Valliant 7kW
I do the same: cool my large buffer (3000L) to 10C, pum...
By upnorthandpersonal , 23 hours ago
-
@editor "The interesting bit is that many modern invert...
By Singlespeed , 24 hours ago
-
RE: Ecodan & MelCloud scheduling
With the prospect of warmer weather this week, I brough...
By downfield , 1 day ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
I reached out to MCS directly last week on this and her...
By Mars , 1 day ago
-
RE: Help me keep the faith with my air source heat pump installation
My heating developed a really severe case of noise and ...
By JamesPa , 2 days ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@l2jad I was just thinking all things being equal. Our ...
By AndrewJ , 2 days ago
-
Hi, Does anybody have experience with Heat Geek insta...
By sttpd1917 , 3 days ago
-
I will soon be struggling. Admittedly it is the summer,...
By Batpred , 3 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
Not known yet. I've asked a local Councillor to follo...
By Transparent , 4 days ago