@heat-pump-newbie Yes you need F Gas engineers like us if a split or monoblock system. Otherwise they just service the heating side of things.
@morgan They may be good but cannot service the heat pump as they don't appear to be F Gas reg, therefore cannot leak check and limited to what they k...
@old_scientist Probably okay if they are servicing the heat pump too, often they just service the heating system indoors as not F Gas qualified. We ch...
Ive called most of them over the years. By far the best seems to be Panasonic, very helpful, calls back if needed and parts required next day delivery...
@jamespa I've tried to find the email but deleted it which means the attachment goes It was quite detailed and did state things that are not quite ac...
@jamespa Thanks for all that info. The part a customer recently sent over about was regarding Part G and it does state must be installed by a reg inst...
@davidalgarve They don't need any special proceedure is what I was saying, just need recovering to a bottle.
@davidalgarve It should just be recovered by both service ports into the recovery cylinder, simple procedure. Maybe try another refrigeration company....
- 26 Forums
- 2,323 Topics
- 52.1 K Posts
- 254 Online
- 5,979 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Electricity price predictions
I think that plan is called net zero! I read somewher...
By JamesPa , 2 minutes ago
-
RE: Solar panels on side of house to heat water
Thank ou all for comments, just to refocus I am not loo...
By paultheheating , 15 minutes ago
-
RE: Mitsubishi Ecodan 11kw Defrosting Issue.
@f1p Thanks for the info, good to know
By ThunderMink , 58 minutes ago
-
RE: Rate the quality of your heat pump design and installation
Sorry, this is long (1 year’s ownership). I bought a ...
By Solenoid , 11 hours ago
-
@toodles I will do, it can’t go any worse than my last ...
By Grantmethestrength , 16 hours ago
-
RE: Configuring third party dongle for Ecodan local control
Yes, it is certainly an advanced feature and quite diff...
By F1p , 17 hours ago
-
RE: MELcloud scheduling misbehaviour
@richard24738 We also want hot water for 7:00am showers...
By DavidAlgarve , 17 hours ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
@hcas Thanks Henri. I take your point, but feel that wh...
By DavidAlgarve , 21 hours ago
-
RE: Replacing my 18 month old Hitachi Yutaki ASHP
The Thermo Off (not Thermal Off) only relates to the la...
By trebor12345 , 22 hours ago
-
RE: Flow rate discrepancy between ASHP and manifold
Ok, I think I have got to the bottom of the problem... ...
By AshRolls , 22 hours ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira vs OVO vs EON.Next vs Boxt
@editor OVO: 'Sorry, we aren't installing heat pumps in...
By stevettweed , 22 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@bash — I also agree, an image based installation is th...
By cathodeRay , 23 hours ago
-
RE: Signenergy AI Mode - How long does it take to learn a usage pattern?
@grantmethestrength What I mentioned is just out of ...
By Batpred , 23 hours ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
Very true, that is the standard method (and the one I u...
By cathodeRay , 1 day ago
-
RE: Our journey through Octopus tariffs 2020-2025
@tim441 guess "every little helps". I plan to let Sol...
By Batpred , 1 day ago
-
RE: Why Millions of UK Homes Struggle With Heat Pumps
If it is combined with the BUS and they make it all goo...
By Batpred , 2 days ago
-
RE: Advice on reading thermal images
@editor Thanks Mars, better price from the website and ...
By colinc , 2 days ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
To be blunt, I wouldn't choose. If we were to move to...
By Majordennisbloodnok , 2 days ago
-
RE: Diagnostic Data Needed for Repeatedly Failing Tesla Powerwall 3 System
Yes, some queries were raised on github recently: ...
By Batpred , 2 days ago