Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Feb 11, 2026
Excellent lateral thinking. Turns out it is a rebadged Midea M-Thermal Arctic. Went to its manual and got this info: Method A(Mode set control)RT c...
I rang Ideal to work out what it was and whether it was useful and they said that they thought it means 'auto mode so it can deliver the right tempera...
@davesoa any idea what 'mode set' means in Room Thermostat setting? No explanation anywhere in manual I can see..
I suspect you are right regarding engineer which is why I've come here. House was still hot even after I changed WC on the iLetcomfort app so went bac...
Hi all I thought I'd give a bit of an update about this. To summarise previous discussions: I was struggling with bills (and a high pitched noise) a...
@davesoa Sorted this, really good. Even seems to have a hot water boost which I couldn't find on the Ideal controller. Only hitch is - it's free so I ...
@ashp-bobba Many thanks for this - I am doing as advised as we speak. Unfortunately I don't know if there is an electric booster heater in the ASHP. ...
Sounds good, thanks a lot I'll check it out - might save me clambering into loft through son's bedroom constantly!
@ashp-bobba just had this through from installer: Space is 184m2 and heat loss is 63W/m2, space heating load is 11.6kW.
@davesoa thanks a lot for this, how does it connect to the controller? I don't have Halo unfortunately.
It doesn't mention flow temp here but don't know how it could say it was my zone 1 temp if it was 35C on my pic..
@jamespa Brilliant thanks. Sorry for this - where do I find the flow temp? Is it on the main display?
- 26 Forums
- 2,618 Topics
- 61.1 K Posts
- 629 Online
- 6,994 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Our 10 year old Grant heat pump failed
Since my last post on this topic we've reached a conclu...
By Mike Patrick , 5 minutes ago
-
Brown Oily Residue Blocking Air Vent and Weeping Relief Valve... Anyone Seen This?
My installation is 4 years old. After about 18 months a...
By seoras , 2 hours ago
-
RE: Renewables & Heat Pumps in the News
An article on funding for heat pumps in case anyone is ...
By Jeff , 3 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Thanks @editor , @indevolt-uk Subject to any comments ...
By JamesPa , 11 hours ago
-
RE: Share Your Experiences with Heat Pump Manufacturer Support
@seoras Sorry to hear that. I found Vaillant very help...
By JamesPa , 11 hours ago
-
The Watchdog That Watched and Waited
On 9 January 2026, Consumer Energy Solutions collapsed ...
By Mars , 15 hours ago
-
RE: GSHP Kaput After 16 Years: New Compressor or Switch to ASHP? Advice Welcome
Cool Energy in Grimsby sell ground source heat pumps an...
By DerekDeLeon , 15 hours ago
-
RE: Valliant Heat Pump Settings
Thats arguably a sign of a good installer - they unders...
By JamesPa , 16 hours ago
-
RE: Electricity price predictions
Well, we have so many cases where rain water mixes with...
By Batpred , 17 hours ago
-
RE: Two heating zones to one zone
@profzarkov They arent obviously wrong, but the only...
By JamesPa , 20 hours ago
-
RE: Towns water feed to air source heat pump system
The DHW circuit cant be separated (well it could, you c...
By JamesPa , 20 hours ago
-
Solis AC-coupled 3kW storage inverter
Solis AC-coupled 3kW storage inverterPylontech batterie...
By MartinRobinson , 1 day ago
-
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer
As @transparent has observed above, this is not bad, an...
By cathodeRay , 1 day ago
-
As I was reading this article Mars, I was thinking that...
By Toodles , 2 days ago
-
RE: Tell us about your Solar (PV) setup
Installed in May 2011: 16*Sharp 245 W monocrystalline p...
By txmartyn , 2 days ago
-
-
RE: Say hello and introduce yourself
That doesn't sound 'right' to me. The national Smart ...
By Transparent , 3 days ago
-
RE: Growatt battery disconnected
I doubt this will happen, but I will try and suggest it...
By Eliuccio , 3 days ago
-
Understood. That's why I decided from the outset on a ...
By JamesPa , 4 days ago
-
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
On the litigation, I would not go there and definitely ...
By Batpred , 4 days ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
I suppose if your pv inverter packs up, you have a plan...
By Batpred , 4 days ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
Firstly check you are using sound power not sound press...
By JamesPa , 4 days ago
-
That’s the solar up and running, I don’t think it’s the...
By David999 , 4 days ago


