Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Feb 11, 2026
Excellent lateral thinking. Turns out it is a rebadged Midea M-Thermal Arctic. Went to its manual and got this info: Method A(Mode set control)RT c...
I rang Ideal to work out what it was and whether it was useful and they said that they thought it means 'auto mode so it can deliver the right tempera...
@davesoa any idea what 'mode set' means in Room Thermostat setting? No explanation anywhere in manual I can see..
I suspect you are right regarding engineer which is why I've come here. House was still hot even after I changed WC on the iLetcomfort app so went bac...
Hi all I thought I'd give a bit of an update about this. To summarise previous discussions: I was struggling with bills (and a high pitched noise) a...
@davesoa Sorted this, really good. Even seems to have a hot water boost which I couldn't find on the Ideal controller. Only hitch is - it's free so I ...
@ashp-bobba Many thanks for this - I am doing as advised as we speak. Unfortunately I don't know if there is an electric booster heater in the ASHP. ...
Sounds good, thanks a lot I'll check it out - might save me clambering into loft through son's bedroom constantly!
@ashp-bobba just had this through from installer: Space is 184m2 and heat loss is 63W/m2, space heating load is 11.6kW.
@davesoa thanks a lot for this, how does it connect to the controller? I don't have Halo unfortunately.
It doesn't mention flow temp here but don't know how it could say it was my zone 1 temp if it was 35C on my pic..
@jamespa Brilliant thanks. Sorry for this - where do I find the flow temp? Is it on the main display?
- 27 Forums
- 2,808 Topics
- 66.3 K Posts
- 2,212 Online
- 7,212 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@rob-of-york Thank you Rob! These are very good suggest...
By SusannaSaunders , 20 minutes ago
-
RE: Marvel Heating liquidation
The interesting thing about the IBG: when I called them...
By davidnolan22 , 1 hour ago
-
Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
The funding for the BUS grant appears to have been subj...
By Rob of York , 9 hours ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
JamesPa The chart explains well how the heat curve an...
By trebor12345 , 12 hours ago
-
RE: Free app: run the immersion / heat pump from Growatt battery & solar surplus – no Home Assistant
Please bear in mind, everyone, that in order to use thi...
By Majordennisbloodnok , 1 day ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis Thanks for posting this and Im so pleased you ...
By JamesPa , 2 days ago
-
RE: I need help with Ecodan ASHP
@f1p It turns out there have been a solar panel install...
By Andris , 2 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews your installer would be right to say that the...
By GrahamF , 2 days ago
-
RE: Tradespeople on Their Phones: What’s Acceptable When They’re Working in Your Home?
Actually, that's a very important point. I've only ev...
By Majordennisbloodnok , 2 days ago
-
RE: Aerotherm and weather compensation
These are likely inked. The basic explanation is tha...
By JamesPa , 3 days ago
-
RE: Electrical works for air to air heat pump
agree with above. I have not had extra costs added wh...
By Batpred , 3 days ago
-
Good to hear that you found a solution. Absolutely a...
By Batpred , 3 days ago
-
RE: Are there any comparisons of DHW heat stores around?
@sarahemmm I have done things the opposite way round I ...
By Toodles , 3 days ago
-
RE: How will removing the standing charge on gas bills benefit heat pumps?
The BUS grant funding for 2026/27 will run out at the c...
By Rob of York , 4 days ago