Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 3, 2026
It is always a good idea to quote sources, some might say it is essential. This time Wattson did get the answer, and it turns out that it is our very ...
Can you post your mathematics and all the data you used? Even things like how you ran the oil heating eg always on or timed? Was the indoor air temper...
@ian33a — a tricky one. Any or all of your hunches may be correct. Can you get the raw data Installers B and C used for their fabric heat losses, and ...
A very good point. In effect, the DHW pipework is an emitter, and very likely not a trivial one, given the figures @jon has previously posted. Maybe w...
@jon — thanks for posting the revised chart, I hope you agree it looks cleaner, and so also less confusing, with same sized blobs. It goes without s...
@jamespa — this chart is indeed suspect, it suggests the energy delivered at low OATs flat lines, which is highly unlikely - unless perhaps some sort ...
@jon — I think you may already have a good estimate of the heat loss, and it is in, or rather can be derived from, this chart: F...
A bit more on ERA5 gridding: This is the size (but not as I understand it the boundaries, the lines are actual lat/long and the ...
Yes, I got that, but it also has dispersed data. Suppose you live in Guildford, which weather station do you use, and how much credibility do you give...
Yes, but @jon used ERA5 data, which is based on NWP modelling. I'm not sure we know how well the modelled outside air temperature (OAT) corresponded ...
- 27 Forums
- 2,810 Topics
- 66.4 K Posts
- 4,609 Online
- 7,215 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Adding data centre electricity costs to domestic energy bills?
Environmental issues: Xlinks say they'll fill their c...
By Transparent , 6 minutes ago
-
RE: Why don't people choose heat pumps?
Surprised that you have to ask that question. Money, ...
By hml1827 , 44 minutes ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Agree with everything else. Personally I think the as...
By JamesPa , 2 hours ago
-
There's a company called Xlinks who are proposing just ...
By Transparent , 4 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 5 hours ago
-
RE: Octopussy cosy 6 experience
@paultheheating Unless things have changed more recentl...
By Toodles , 21 hours ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 1 day ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 2 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 2 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 2 days ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@etchedpixels Agreed, just a thought for others. I am...
By Watcher , 3 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 4 days ago
-
Coming back on subject... A shortened version of the ...
By Transparent , 4 days ago
-
RE: Say hello and introduce yourself
Perhaps it is time for an update on ‘our’ project. We h...
By Toodles , 4 days ago



