Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering youāll be able to ask questions, join discussions, follow topics youāre interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 10, 2026
@batalto - OK, thanks, now done. I did turn the DHW off and room stat down. A fair amount of crud, but that is after almost two months of near continu...
@batalto - thanks, I will check the filter and report back. Before I check it, presumably you need to turn the heating and DHW off before doing it?
@batalto - it would be interesting to compare flow rates, given we have similar units. I haven't cleaned the gauze filter, the one adjacent to the hea...
Some measurements from 0800 this morning: Midea controller: ambient 11 LWT 41 RWT 35 capacity 0kW flow 0.83M3/H current 0A Room temps (design temp...
@cycleneil - no, its controlled by an on/off room stat in the kitchen, currently set to 21 degrees, kitchen design temp is 19 degrees, so most of the ...
The rads are actually Ultraheat branded, and the output per size varies slightly between different manufacturers. My installer went with a certain sup...
Exactly, that is why I am increasing thinking it is a compound problem, both the heat pump capacity is inadequate at low ambients and the heat that is...
I wasn't meaning to be harsh (and note that I chose a Midea over a Mitsubishi, for various reasons, including it must be said its low profile design b...
Current (0915h) flow/return temps and top middle rear panel rad temps: Midea controller: Ambient: 7; LWT 47; RWT 41 PHE pipework: Primary in 45; p...
This gets complicated. Firstly there is the nominal output, as listed in the catalogues, usually at a delta t of 50. A correction factor then has to b...
@derke-m - Argghhh!!!! The forum has just deleted my reply. very frustrating. 'Something went wrong with your submission' or words to that effect, and...
@derek-m - OK, here are some minute by minute readings, col head abbreviations as before, csv text format. Ambient throughout was 5 degrees: Time,LW...
- 27 Forums
- 2,762 Topics
- 65 K Posts
- 603 Online
- 7,168 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Vaillant Aurotherm - Heater Wire Position
Ah, good point. I need to check if this was installed i...
By Batpred , 1 hour ago
-
RE: Adventures in heat loss calculations
Posted by: @jamespa At this point its probably worth...
By Rob of York , 3 hours ago
-
@batpred thanks for getting a copy. Appreciate the supp...
By Mars , 13 hours ago
-
RE: Tell us about your Solar (PV) setup
We have a 6.56kW solar PV system (16x 410W panels) inst...
By Rob of York , 18 hours ago
-
RE: Where heat loss surveys seem to go against practical reality
@cathoderay @jamespa I've managed to get some nice re...
By Rob of York , 2 days ago
-
RE: 7kW EV Charger Options Advice
Doh, not sure that I was thinking straight there, less ...
By Rusty , 2 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
Iām really liking reading through this thread and the r...
By Judith , 2 days ago
-
Thank you @trebor12345
By rgabor , 2 days ago
-
Panasonic Free Multi Z and Etherea Internal units.
My prospective installers have suggested the Panasonic ...
By Toodles , 3 days ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
Great. You just need to find a way of cranking up your...
By JamesPa , 3 days ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
We had two heat pumps installed without Govt funding. H...
By Rob of York , 3 days ago
-
My Adapt is finally installed and running! Almost a yea...
By tomasmcguinness , 3 days ago
-
-
RE: Being screwed over by Volkswagen Audi Group
Thanks, @batpred. That integration is the one I have in...
By Majordennisbloodnok , 6 days ago