Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

cathodeRay
cathodeRay
@cathoderay
Moderator
Famed Member
Joined: Feb 28, 2022
Last seen: Oct 24, 2026
Topics: 18 / Replies: 3076
Reply
RE: 14kW Midea ASHP in an old leaky building

@kev-m, @mjr, @mookyfoo, @derek-m - thank you all for your comments. I did do the setback over Sunday to Monday night (to 16 degrees on the kitchen ro...

4 years ago
Reply
RE: -5c this weekend!

My hope, if I ever need to do this, is that it will increase energy use and so costs (obvs, 14 => 16kW), but it should not adversely affect COP (mo...

4 years ago
Reply
RE: ASHP Retrofit in a 2015 house with 10mm radiator tails

In the meantime, I've tracked this down, it is the so called radiator exponent n equation, which is used by rad manufacturers to calculate their corre...

4 years ago
Reply
RE: 14kW Midea ASHP in an old leaky building

I'm putting this here because it is in effect a continuation of this thread. For the past week, I have been fine tuning my heating always on weather...

4 years ago
Reply
RE: ASHP Retrofit in a 2015 house with 10mm radiator tails

I had a number of installers take similar positions. They are jobsworths, hiding behind regulations. Solution? Fire them.

4 years ago
Reply
RE: ASHP Retrofit in a 2015 house with 10mm radiator tails

It's a minefield. In fact the whole thing is a minefield. As I have said before I prefer using a correction factor, ie you down rate the rads outpu...

4 years ago
Reply
RE: What's your current daily damage?

As it happens, I have been a fairly close eye on things for the last week. First up, context. Three bed leaky old building in Southern England. Hour...

4 years ago
Reply
RE: ASHP Retrofit in a 2015 house with 10mm radiator tails

I wonder if this is something we don't give enough consideration to. I too have noticed my heating takes a very long time to reach temp, sometimes mea...

4 years ago
Reply
RE: ASHP Retrofit in a 2015 house with 10mm radiator tails

@alistairgbarron - I had similar painful hoops to jump through, and had the additional constraints caused by a small listed building, the listing limi...

4 years ago
Reply
RE: ASHP Retrofit in a 2015 house with 10mm radiator tails

I had a few installer quotes based on the MCS software. They didn't get the job. Good that you are double checking things, typos are easy to do.

4 years ago
Reply
RE: ASHP Retrofit in a 2015 house with 10mm radiator tails

@alistairgbarron - sorry, I see now that you are already well ahead of the game on the calculations. I also got a bit confused by the thread/post re-a...

4 years ago
Reply
RE: How many installers do you think have heat pumps at home?

Then the next even more interesting question might be: "Would you still have installed a heat pump if you hadn't been bribed sorry 'incentivised'?" Th...