Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

cathodeRay
cathodeRay
@cathoderay
Moderator
Famed Member
Joined: Feb 28, 2022
Last seen: Sep 9, 2026
Topics: 18 / Replies: 3023
Reply
RE: Vaillant Arotherm yeild and COP readings

@bristoljoe - the old oil system and the new heat pump system both did and do the same work, heating and DHW. The heat pump has only about 1.5m of ext...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

@derek-m - still trying to make sense of that climate.py code. One observation: the DHW tank actual temperature isn't defined in that climate.py code,...

4 years ago
Reply
RE: Vaillant Arotherm yeild and COP readings

This heat delivered by heat pumps thing is a bit of an enigma. I am off mains gas, and used to have oil CH. In a typical heating season, I might use 1...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

@filipe - although much of the 'how to' has ended up ad hoc in this thread, I am going to try and write it up in a more structured way in my Beginner'...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

@derek - I think it will be outdoor_temperature, the AC (air conditioning) Midea devices use this, and no reason to suppose C3 devices (heat pumps) ar...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

@derek-m - I've added the latest code changes. There was a typo you might like to correct in your version (self.outside_temperature = body[data_offset...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

You posted while I was writing my last post, I will make the changes now. I meant to say earlier, I think the second byte is heating/DHW status. Se...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

Only yesterday, I was thinking that anyone who manages to decipher the Midea code deserves a Turing award. They are in the same order as in the c...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

@derek-m - last night's hourly 'byte' values after hex2dec conversion and my assessment (colour bars) of what is what: The current C3\message.py c...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

Aha, I think I've got it. Let me put it like this. I thought the message was the data stream, but in fact the message is built by plucking elements fr...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

I doubt we will get -12C in the near future! In fact, I think we are unlikely to get much below zero during this week, if that. I will watch the local...

4 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

@derek-m - at the moment (13:24) the wired controller outdoor temp shows 12 degrees, maybe it was 11 degrees. At 1308 (one of the random not on the ...