Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 21, 2026
Indeed. The apparent cycling seen at 4 degrees and below isn't modulating cycling, it's defrost cycles, and by doing them, the heat pump shoots itself...
I have just thought of a register that I know has a negative number: the left hand end of the WCC OAT is set to -4 degrees C. When I read it without a...
I think you have hit the nail on the head. Here is a read request to address 107 (OAT) in debug mode which also shows the actual response received: ...
I'm pretty sure it is my data, I posted it here on the forum not so long ago. The real world cycling varies a bit, but is typically around twice ...
Here is the actual Set LWT vs OAT (ambient temperature) for my heat pump for all available dates (late March 2023 to date, when running, always in WC ...
@jamespa - I'm planning to alternate setback plus recovery boost, ie the auto-adapt script, with periods of standard 24 hour running, building up roug...
Indeed. It is a very dynamic situation, with lots of variables constantly changing and interacting. At least with observed data, assuming it is accura...
I've scanned through the data I have, which although at first glance seems like it is a lot of data, it is in fact only five weeks or so at the end of...
You should be fine, they are not complex queries, with the csv file(s) becoming the tables you select from. The sql 'dialect' is sqlite, which, as you...
Correct, the actual measurements (upper plot) shows some cycling on the LHS, the model (lower plot) does not.
What I do is have the data in csv format, which I can then load into a text editor, such as Notepad++, and extract slices at will. I also use python's...
I suspect a more accurate answer may be that D wants to paint a picture that has D and J as sage old chaps having a learned chinwag in the library whi...
- 27 Forums
- 2,798 Topics
- 66.2 K Posts
- 2,122 Online
- 7,202 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Passiv Smart Thermostat - Help & Forum Support
Obviously the weather is changeable but there's a defin...
By Singlespeed , 16 minutes ago
-
RE: Double or Triple Glazed Windows?
It is very comforting to see the condensation on the ou...
By Toodles , 19 minutes ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@rob-of-york I must admit that when we had a Daikin hea...
By Toodles , 44 minutes ago
-
RE: Forum updates, announcements & issues
Get the Renewable Heating Hub heads-up on WhatsApp. I...
By Mars , 2 hours ago
-
RE: Safety study for plug in batteries out to tender - looks like Q3 2027 at best before legal
@editor I pointed out to the one of the Fuse execs that...
By dansus , 2 hours ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews As well as loft insulation, there are othe...
By Rob of York , 4 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
On the money, @editor. Until manufacturers stop actin...
By Majordennisbloodnok , 5 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Google Cloud outage: Let's not jump to the conclus...
By Transparent , 5 hours ago
-
RE: BT cuts you off, Plusnet blames Openreach... welcome to “seamless” broadband switching
Both of which (in most cases) use Openreach for the las...
By JamesPa , 5 hours ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
@technogeek agreed. I’ve stopped the setback since tha...
By AndrewJ , 6 hours ago
-
RE: Renewables & Heat Pumps in the News
Yes, this is a swiss and german standard I believe, Vai...
By Batpred , 20 hours ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@editor FWIW my problem was resolved, eventually, after...
By BigFish , 1 day ago
-
My heating has been off and DHW on throughout the summe...
By DavidAlgarve , 1 day ago
-
RE: Anyone concerned about GivEnergy?
The GivE forum seemed to have survived the collapse of ...
By downfield , 1 day ago
-
RE: Cooling/heating with one unit
@mrkfm The Solo has a small capacity and only suitable ...
By dgclimatecontrol , 1 day ago