Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

cathodeRay
cathodeRay
@cathoderay
Moderator
Famed Member
Joined: Feb 28, 2022
Last seen: Sep 6, 2026
Topics: 18 / Replies: 3001
Reply
RE: Outcome for 2024 - with Agile, ASHP, PV, Batteries, EV

Great, and good luck! Do take your time, the old think three times, measure twice and cut once routines. If you have any questions, don't hesitate to ...

2 years ago
Reply
RE: Outcome for 2024 - with Agile, ASHP, PV, Batteries, EV

As I'm on the case... It looks like these are the LG modbus wire connection terminals, from this HA thread:

2 years ago
Reply
RE: Outcome for 2024 - with Agile, ASHP, PV, Batteries, EV

I think you are in luck. I found this in a LG Therma V manual: Register 30003 looks like the RWT (returning water temp), 30004 the LWT (leavin...

2 years ago
Reply
RE: Outcome for 2024 - with Agile, ASHP, PV, Batteries, EV

That suggests a possible modbus connection. If you have or can get a service manual for your particular heat pump model, you might be able to find out...

2 years ago
Reply
RE: Double heat pump for DHW?

There is another option. Have a bath once a month (whether you need it or not).

2 years ago
Reply
RE: Outcome for 2024 - with Agile, ASHP, PV, Batteries, EV

This appears to be another example of heat loss calculations over-estimating heat loss significantly, something that old buildings appear to be prone ...

2 years ago
Reply
RE: Best control strategies for heat pumps that are way oversized

If I have read and copied the Midea data tables correctly, I am not sure I can see much 'efficiency' difference between a smaller heat pump running fl...

2 years ago
Reply
RE: Best control strategies for heat pumps that are way oversized

Midea and I suspect other manufacturers do have detailed tables of heat pump outputs and i suspect it should in theory at least be possible to compare...

2 years ago
Reply
RE: Best control strategies for heat pumps that are way oversized

I am not sure we fully understand either the supposedly harmful or indeed the potentially beneficial effects of cycling, eg when a heat pump uses it t...

2 years ago
Reply
RE: Best control strategies for heat pumps that are way oversized

Not to mention python scripts, but a room stat / timer solution is the sort of thing people can set up without complex knowledge of heat pump controll...

2 years ago
Reply
RE: Best control strategies for heat pumps that are way oversized

Can't a room stat with timer achieve that? It would need enough on/off times per 24 hours, then just set the desired temp very high/very low. HDHD (...

2 years ago
Reply
RE: Heat loss calculators and spread sheets

I think it is possible installers may consciously or subconsciously welcome this, because it allows them to over-size on the back of what looks like a...

2 years ago