Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Batpred
Batpred
@batpred
Member
Noble Member
Joined: Jan 3, 2025
Last seen: Aug 26, 2026
Topics: 11 / Replies: 1103
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

I used the term head like I heard the electricians use it. A year ago, I had some issue (some loose contact that was causing it to heat). I had to cal...

8 months ago
Reply
RE: Solis inverters S6-EH1P: pros and cons and battery options

🤣 Well, I never managed to get the HA solis "sensors" properly configured on HA´s batpred, (I tried to leverage the solis Modbus integration...

8 months ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

Indeed! And my apologies, I should have expected you had assessed it. 😊 And I also found the reason for the multiple categorisations ...

8 months ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

When the grid is off, there it could be that the neutral cable is interrupted. In this case, there´s no earthing! Chances are that if that happens, it...

8 months ago
Reply
RE: Setback savings - fact or fiction?

Given the weather has been relatively stable, the empirical results seem worth sharing. 🙂 I am assuming it is condensing I dropped the maxim...

8 months ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

Ok. I am concerned that the earthing arrangement being as below, it should have a rod added to it. I am curious since one EICR reported it as TN-S,...

8 months ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

The diagram below is a simplified view of the internals of the Solis S6 hybrid. The earth shows against the grid port connects to the consumer unit...

8 months ago
Reply
RE: Power outages and storms: A surprisingly good DNO experience

Exactly what came to my mind. Octopus is one of the few where the employees will explain where they have a limitation or challenge to address whatever...

8 months ago
Reply
RE: Running from backup generaor in powercut?

As the Iberian blackout reminded us, anything you don’t exercise now and then can show a habit of sulking when you really need it… 😄One small...

8 months ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

The diagram describes what happens inside the Solis. All these relays are electronically controlled by the firmware it runs. By bonding I understan...

8 months ago
Reply
RE: New Fogstar 15.5kWh upright solution

Clearly, we have to be very careful with comparisons. It is up to each individual or company to decide on what they see as comparable. Having said ...

8 months ago
Reply
RE: Solis inverters S6-EH1P: pros and cons and battery options

Solis confirmed that the S6 works with a single battery (pack) via CANbus. So the BMS connected via CANbus needs "to take care" of any communication r...

8 months ago