Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 13, 2026
@batpred Your BMS parameters will be the same as mine then, as I only changed the Fogstar recommended ones in the tutorial (which are largely irr...
@batpred Interestingly having had a very quick look at your BMS settings, they look totally different to mine, not the values themselves, but the l...
@batpred There's no magic, it is the design of the BMS, I have watched it many times from the stock firmware unchanged. You need to set your alar...
@batpred As I said you are looking at the wrong thing. You need to be connected to your BMS direct. I am using the default settings of the BMS,...
@batpred There is no configuration required to the Seplos BMS settings. The BMS automatically does this for you. I know that it does it as I spen...
Thanks @transparent Thankyou for your advice as it helped me make sure I ordered the right one!
@batpred I don't recognise that screenshot you have posted. I spent many nights working out why the unit's weren't balancing as well as I'd hoped ...
@johnnyb They started supplying the Seplos units with the new JK 2A active balancer about 6 months ago. I bought 3 packs. The last one I bought a...
@batpred No. Mine, as yours, came with the Seplos V3 BMS. It also came with a Seplos Active balancer, which is rubbish. Fogstar Found that out qu...
@batpred I have an MPAN also, so would be the same process as you. I just need to decide if it's worth the couple of hundred pounds to get a few ...
@jancold From my observations the Seplos V3 BMS that comes in the Fogstar Seplos units ramps down the charge rate as it approaches capacity. &nbs...
From my observations the Seplos V3 BMS that comes in the Fogstar Seplos units ramps down the charge rate as it approaches capacity. This leaves plen...
- 27 Forums
- 2,781 Topics
- 65.6 K Posts
- 1,286 Online
- 7,187 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Tesla Powerwall (2) Calibration Cycles
@old_scientist You mean you didn’t know about that secr...
By Toodles , 3 hours ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
That sounds like a better approach (being able to see a...
By cathodeRay , 3 hours ago
-
RE: DIY Heat Pump Installations: Navigating Legal and Regulatory Hurdles
Thanks for the reference @jamespa I can't see any te...
By Transparent , 5 hours ago
-
RE: battery storage without solar
Indeed, current on the grid input = current used for ch...
By bobflux , 5 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu @papahuhu A lot of tears and sweat went into ...
By Andris , 8 hours ago
-
RE: Getting closer to a finished Haier system
Very nice! Congratulations. Big MLC looks neat whe...
By bobflux , 13 hours ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
We have the same problem, 12 mature trees clip the morn...
By Papahuhu , 1 day ago
-
RE: Solis inverters S6-EH1P: pros and cons and battery options
I had a battery and inverter installed a while ago, my ...
By Batpred , 1 day ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
@ltron2 The EPC on our house is A-92, however that i...
By Rob of York , 1 day ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
The layout is confusing - much better like this: We b...
By downfield , 2 days ago
-
RE: Is it just me, or does tradesperson timekeeping and communication drive you absolutely mad?
My experience, backed up by opinions from various frien...
By Majordennisbloodnok , 2 days ago
-
RE: Analysis of the economics of switching to an A2W ASHP compared to other heat sources
I had a meeting today with a company based out of Swede...
By Mars , 3 days ago
-
RE: Review your electricity provider
We were with Octopus in our old house and it was fault...
By ian33a , 3 days ago
-
RE: Estimating true heat loss from twelve months of consumption data
I did, indeed, go with the 12 KW Vaillant unit.  ...
By ian33a , 3 days ago