Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Dec 24, 2024
@david999 I haven't seen glycol in a system for about 2 years if I'm honest. Anti freeze valves all the way for me. Glycol is horrible stuff that make...
@david999 the student will become the master 😀
@david999 I was trying to be lenient on the installers but that's taking the "biscuit". Good luck and post how you get on 👍
@david999 haha atleast the freezing was resolved. Isolation valves around the 3 port would be nice as long as they are full bore (full flow) althoug...
@david999 Hi David, that all seems fairly reasonable, and if Samsung have signed off on it and you have that in writing then great. It is alarmingly c...
@david999 That pump is a very small 6m head pump, I think at your target of 45lpm that pump can only produce something like 1.8m head. The pressure...
@david999 If you had 36-40lpm I would accept as you know it would atleast be able to supply enough heat for your particular property, with only being...
@david999 11.19kw heat loss means that you need a minimum of around 35-36l/m to meet the heat load at the design temperature, if you are only getting ...
@david999 Hi David, sorry I'm not quite sure what you mean? Heat pump systems can go into 100's of kw, even megawatt systems. If your heat loss is i...
@david999 if it's an MCS registered install you must be given a copy of the heat loss calculations which should be your starting point. 29lpm is rou...
@david999 out of interest what was the heatloss figure for the property? 46lpm is correct for a 16kw heatload, however the Samsung can only output a...
@toodles You have 3 settings on the PWM settings in the MMI controller. You can set it to: UFH which is slow response, adjustable DT Fan convect...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 648 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Thanks for the update. Vaillant is a good choice, their...
By Batpred , 16 minutes ago
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
@penval, really useful update. After all the discussion...
By Mars , 7 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 1 day ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 1 day ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 1 day ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 1 day ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 2 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 2 days ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 2 days ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 3 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 4 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 4 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 4 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 5 days ago