Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Dec 24, 2024
@david999 I haven't seen glycol in a system for about 2 years if I'm honest. Anti freeze valves all the way for me. Glycol is horrible stuff that make...
@david999 the student will become the master 😀
@david999 I was trying to be lenient on the installers but that's taking the "biscuit". Good luck and post how you get on 👍
@david999 haha atleast the freezing was resolved. Isolation valves around the 3 port would be nice as long as they are full bore (full flow) althoug...
@david999 Hi David, that all seems fairly reasonable, and if Samsung have signed off on it and you have that in writing then great. It is alarmingly c...
@david999 That pump is a very small 6m head pump, I think at your target of 45lpm that pump can only produce something like 1.8m head. The pressure...
@david999 If you had 36-40lpm I would accept as you know it would atleast be able to supply enough heat for your particular property, with only being...
@david999 11.19kw heat loss means that you need a minimum of around 35-36l/m to meet the heat load at the design temperature, if you are only getting ...
@david999 Hi David, sorry I'm not quite sure what you mean? Heat pump systems can go into 100's of kw, even megawatt systems. If your heat loss is i...
@david999 if it's an MCS registered install you must be given a copy of the heat loss calculations which should be your starting point. 29lpm is rou...
@david999 out of interest what was the heatloss figure for the property? 46lpm is correct for a 16kw heatload, however the Samsung can only output a...
@toodles You have 3 settings on the PWM settings in the MMI controller. You can set it to: UFH which is slow response, adjustable DT Fan convect...
- 27 Forums
- 2,745 Topics
- 64.5 K Posts
- 1,678 Online
- 7,149 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
@davidb I can’t help you with contacts at Vaillant unfo...
By Mars , 4 hours ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@Ian-S, I actually think this is a pretty reasonable pl...
By Mars , 4 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@toodles I invested on Miele a pair of frodge frozor wh...
By AgentGeorge , 8 hours ago
-
RE: Flushing system, cleaning and inhibitor
Flush and fill all complete. Octopus kindly gave us a...
By Old_Scientist , 8 hours ago
-
RE: Wood burner with ASHP - direct air?
For what it's worth I installed a wood burner in this o...
By BlizzardGreen , 9 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
I think I saw a diagram for an exhaust air dhw tank wit...
By JamesPa , 1 day ago
-
RE: Indevolt Batteries UK Support & Info Thread
Thanks, however that's an answer to a subtly different ...
By JamesPa , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles Such elegant symmetry. look at my lumpy bag of...
By Papahuhu , 4 days ago
-
RE: PV and battery long payback - sense check query
Quite probably not, but you can get a 32A relay and a S...
By JamesPa , 5 days ago
-
I don't notice mine defrosting, and most of the time Im...
By JamesPa , 5 days ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
Kind of you, @calumm, but it was @f1p who did the heavy...
By Majordennisbloodnok , 6 days ago
-
RE: Electricity price predictions
2. As EV ownershp increases it'll certainly increase de...
By EtchedPixels , 6 days ago