Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering youâll be able to ask questions, join discussions, follow topics youâre interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Dec 24, 2024
@david999 I haven't seen glycol in a system for about 2 years if I'm honest. Anti freeze valves all the way for me. Glycol is horrible stuff that make...
@david999 the student will become the master 😀
@david999 I was trying to be lenient on the installers but that's taking the "biscuit". Good luck and post how you get on 👍
@david999 haha atleast the freezing was resolved. Isolation valves around the 3 port would be nice as long as they are full bore (full flow) althoug...
@david999 Hi David, that all seems fairly reasonable, and if Samsung have signed off on it and you have that in writing then great. It is alarmingly c...
@david999 That pump is a very small 6m head pump, I think at your target of 45lpm that pump can only produce something like 1.8m head. The pressure...
@david999 If you had 36-40lpm I would accept as you know it would atleast be able to supply enough heat for your particular property, with only being...
@david999 11.19kw heat loss means that you need a minimum of around 35-36l/m to meet the heat load at the design temperature, if you are only getting ...
@david999 Hi David, sorry I'm not quite sure what you mean? Heat pump systems can go into 100's of kw, even megawatt systems. If your heat loss is i...
@david999 if it's an MCS registered install you must be given a copy of the heat loss calculations which should be your starting point. 29lpm is rou...
@david999 out of interest what was the heatloss figure for the property? 46lpm is correct for a 16kw heatload, however the Samsung can only output a...
@toodles You have 3 settings on the PWM settings in the MMI controller. You can set it to: UFH which is slow response, adjustable DT Fan convect...