@iancalderbank Yup, tried that, but the tank maxes out at 55degC indicated on the cylinder. The immersion thermostat cuts in and it then cycles on tha...
@derek-m thanks. The immersion heater thermostat on Grant cylinders is pre-set to 65degC and it cycles on/off on that. However, the separate cylinder ...
Much of the struggle with ASHPs in winter is the defrost method. ASHP Evaporator coils have very narrow fin pitch, 1 to 1.5mm. That gives a large surf...
You may need a mains pressure regulator on the cold water inlet to your house. The pre-plumb cylinder inlet manifold has a 3bar pressure relief valve ...
This is interesting @sunandair. The basic weather compensation, relying solely on instantaneous outdoor dry bulb temperature, is crude. I've wondered ...
This is interesting @sunandair. The basic weather compensation, relying solely on instantaneous outdoor dry bulb temperature, is crude. I've wondered ...
@marvinator80 it does this with my 10kW. Algorithm within the ASHP as it monitors air and return water temperature. It’ll turn the ASHP off for a leng...
I think it's a monobloc unit, R410A. See here:which is probably why they are getting flogged off cheap by the likes of Appliances Direct, to unsuspect...
With a DIY install you've got the option for heating and also cooling via fan coil units, which under the MCS approach isn't an option. However, these...
Yeah, exactly my concern. What are the briquettes made of (waste product or felled timber) and how much CO2 and energy goes into their process that pr...
I've looked at this company several times but never taken the plunge. They get good reviews. My only concern is the Lekto supply chain is opaque, they...
- 26 Forums
- 2,104 Topics
- 46.3 K Posts
- 154 Online
- 3,393 Members
Join Us!
Latest Posts
-
RE: Location of hot water isolation valve on cylinder
@transparent Thank you so much and very helpful. Earlie...
By rossowheels , 12 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@toodles Indeed. On a tariff such as IOF where import a...
By Old_Scientist , 12 hours ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
It does indeed look like that, @skyefarmer. There is ...
By Majordennisbloodnok , 19 hours ago
-
RE: Plug and play solar. Thoughts?
Have a read of my previous posts on so-called Balcony S...
By Lucia , 2 days ago
-
@editor @bart Hi, I can see a few problems with your in...
By Brendon Uys , 2 days ago
-
RE: Compressor attempts start but fails - Nibe Fighter 2005 8kW
"To tell you the truth, I don't know if HAL is homicida...
By Scalextrix , 2 days ago
-
The Importance of Radiator Balancing for Efficient Heating: Introducing the Flow Regulating Valve
It’s fascinating to watch how low-temperature heating i...
By Mars , 3 days ago
-
RE: Servicing Hitachi HP in rural Somerset
I'd give GreenGenUK a call or email them: sales@greenge...
By Mars , 3 days ago
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 3 days ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 3 days ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 4 days ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 4 days ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 4 days ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 5 days ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 5 days ago