RE: Very noisy Daikin Altherma

@Sobo, you could ask your installer to provide their complete MCS020 acoustic calculation estimate to you, if you don't already hold it. P.16 onwards ...

2 years ago
Reply
RE: Very noisy Daikin Altherma

@sobo attach some pictures if you can please? It's a new install under MCS, the white noise of the fan impeller plus a hum (not a rattle) of the compr...

2 years ago
Reply
RE: Very noisy Daikin Altherma

Manufacturer's noise levels are usually quoted dB(A) SPL @ 1m free field. This means no reflective surfaces such as walls or floors. It's an unrealist...

2 years ago
Reply
RE: Zehnder ComfoPost CW6 with ASHP?

If you want to include cooling, have you considered air to air heat pumps? Depends on the number of rooms you consider needing cooling, and the visual...

2 years ago
Reply
RE: Rota Disconnections

Modern monobloc heat pumps will not be harmed by power cuts. They don't have a refrigerant pump down system as the low charge quantity doesn't necessi...

2 years ago
Reply
RE: Solar Performance

@toodles thank you. Profile of your monthly generation matches mine. Last two months were a bit lower. Year to date solar production has been 2.9MWh. ...

2 years ago
Reply
RE: Solar Performance

Useful 5 year month-by-month comparative data there @editor. Thank you. August has been something of a solar wash-out for us in the North East. That s...

2 years ago
Reply
RE: 17kw Grant Aerona heat pump not performing

@hughf Chofu use an end suction centrifugal pump however, not an in-line pump. Chances are only the OEM pump will fit.

2 years ago
Reply
RE: 17kw Grant Aerona heat pump not performing

It really sucks Sonix, you've tried to do the right thing and been badly let down. I would be surprised if the plate heat exchanger is badly blocked, ...

2 years ago
Reply
RE: 17kw Grant Aerona heat pump not performing

Hi @Soniks, that's really bad news. Has the ASHP installation been installed by a Grant G1 approved installer? If it has, and is has been serviced and...

2 years ago
Reply
RE: Auxiliary Heating

My Grant has an auxiliary output contact, which is used to control a separate 3kW immersion heater via a relay. It's a back-up heater, supplementary h...

2 years ago