Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 10, 2026
TRV;S are standard manual ones . Samsung controller is connected by a Danfoss TP5000 Si It is on a 5/2 day/week program 4slots in 24 . I gues it can b...
OK , I have read the above . I have moved each programme for 24 hours to 2 degrees above disired slots as I am using Octopus Cosy , boosting on the...
Ah Ok , so when I think I have balanced rads at say to 22c then set room stat above by 2 degrees and if it makes the room temp too warm turn down lock...
Moving on a bit , I had all the rads where I wanted them at WL 44C. Rooms near the Movable room stat 22 . Smaller ones near 20c (Bedrooms) mainly. I...
Not sure if this is working , smaller rooms a bit colder and larger a degree off the 22c . Having said that I observe that pump is on but only showing...
Thanks ! Head banging , haha !
I have just carried out your advice and I am within .5c of whatever the Rads I want at maximum in relation to room temoerature. How do determine WL ON...
Read your Red Flags with interest. Presently tweaking my system and getting the flow temperatures down as for the past 8 yrs It has been set at 50c ...
Intrigued by this conversation , I thought I would attach the spec of My Samsung . I assume by the fact it says inverter technology, it has soft start...
Oh my , , I am completely out of my depth here, if I read you right it’s not a good idea ? I you like , I can send you my proposal .
Currently resetting Flow temps as per my thread adjusting lockshield valves. Low temps -5c for Scotland Max temps 15c It has been 50c for years ...
@abernyte I can send the quote , if you can understand the figures on it I would love your opinion , I’m just a bit in the dark .
- 27 Forums
- 2,756 Topics
- 64.8 K Posts
- 1,338 Online
- 7,160 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: 7kW EV Charger Options Advice
I was hoping that the electrician would route the under...
By Rusty , 3 hours ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
@jamespa @transparent Sorry about that. Here are the ch...
By jon , 3 hours ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@tim441 Yes, I too am waiting for V2H before I get an E...
By Papahuhu , 5 hours ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
Post by: @old_scientist The first thing I would say ...
By Rob of York , 8 hours ago
-
RE: Adding additional Solar Panels to a DC coupled battery system
@transparent thank you for your reply above. As alway...
By Old_Scientist , 14 hours ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@kilgorexv definitely a larger inverter will help and m...
By AndrewJ , 2 days ago
-
RE: Adventures in heat loss calculations
@rob-of-york — thanks for posting this, all very useful...
By cathodeRay , 2 days ago
-
RE: Surface mount or bury primaries for heat pump installation?
The installation is almost done! I've written up two ...
By tomasmcguinness , 3 days ago
-
RE: Glass lined Cylinder for private water supply
This has turned into a fascinating little rabbit hole. ...
By Mars , 3 days ago
-
RE: Switch suitable to change between two inverter CT's
Last winter my battery ,32KWh, could run the house com...
By Jancold , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Agree with Major. And even if I was very happy with ...
By Batpred , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
There is another estimator that you could use, a formul...
By Rob of York , 3 days ago
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
@penval, really useful update. After all the discussion...
By Mars , 5 days ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 6 days ago