I have mine set to 25C (although I doubt my system can really do much at that temperature due to undersized radiators) and 45 degrees (as much above t...
@afarmery I would start by setting it to 60mins and if the controller isn't reacting quick enough to maintain the desired room temperature keep loweri...
I've been watching this tread and trying a few of the settings on my Ecodan 8.6kW. Currently our FTC6 main controller is in the hallway but we haven...
Guilty as charged. I posted that on OEM forum then had a look on here to see it was a hot topic.
Forum Handle: @ajdunlop Manufacturer: Mitsubishi Model: Ecodan R32 8.5kW (PUZ-WM85VAA) Type: ASHP Arrangement: Mono Area of Country: West Y...
I'm still trying to get my head around our office Ecodan 8.5kWh which is operating in Auto Adaptive mode using the main controller's thermostat. Her...
Carrying on the conversation about Auto Adaption mode. Our office Ecodan has been running in AA mode for a while. It is set to ramp up from a ...
The waiting is killing me, any chance of some findings so far? I went a bit mad with the settings last week (should have changed one at a time t...
How many Heat Pumps can actually vary the pump speed. I know the Ecodan can't. It seems odd that they all can't control the pump speed to maximise e...
@mjr excellent thanks for that. I’ll let it run for a bit longer. Think I’ll dial the interval down to 20mins and see what happens. Also might reduc...
@kev-m Yea, I might try reducing the maximum flow temperature (although don't want to do this too much as it may need to go higher when really cold). ...
- 26 Forums
- 2,102 Topics
- 46.2 K Posts
- 51 Online
- 3,388 Members
Join Us!
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist I found the switching between tariff jus...
By Toodles , 30 minutes ago
-
RE: Plug and play solar. Thoughts?
Have a read of my previous posts on so-called Balcony S...
By Lucia , 3 hours ago
-
@editor @bart Hi, I can see a few problems with your in...
By Brendon Uys , 6 hours ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
Well at least that solves the mystery of where the exce...
By JamesPa , 8 hours ago
-
RE: Compressor attempts start but fails - Nibe Fighter 2005 8kW
"To tell you the truth, I don't know if HAL is homicida...
By Scalextrix , 8 hours ago
-
RE: Location of hot water isolation valve on cylinder
@rossowheels if you isolate the water supply in it will...
By ASHP-BOBBA , 1 day ago
-
The Importance of Radiator Balancing for Efficient Heating: Introducing the Flow Regulating Valve
It’s fascinating to watch how low-temperature heating i...
By Mars , 1 day ago
-
RE: Servicing Hitachi HP in rural Somerset
I'd give GreenGenUK a call or email them: sales@greenge...
By Mars , 2 days ago
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 2 days ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 2 days ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 2 days ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 3 days ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 3 days ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 3 days ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 3 days ago