Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Feb 13, 2024
I may review my decision about this over time. [Circulator] Pump modbus is over TCP/IP, the Heat Pump is over RS485. Screen shot is of flow rate x 2...
There seem to be multiple views on this, simple cheap two wire, shielded and grounded at one end only, shielded and grounded on both ends. I decided ...
@tomc I think I have solved my problem. If you want flow rate, outside temperature and a couple of others, it seems these are in the group of "New Mo...
@cathoderay I have been a Home Assistant for many years, and there is a bit of learning curve. All you will need is a PC or RPi, then install the f...
I think I worked it out, I need to enable the register messages before the flow rate, and some other registers will start working. Did not page far ...
I now have the modbus connected and installed in my Samsung 16kW Gen6. I wondered if you could share your modbus config. I have all the config set ...
I am struggling to understand why heat pumps can't be installed properly. I have a pretty old house where the insulation level is measured by "wind c...
You need to check the building regs on that. Not block and beam, but we did have 100mm concrete 150mm celotex and 100mm concrete, this for a poli...
Exactly. I don't have the experience to know the "practical tricks of the trade" as it were, just a background that makes the maths relatively easy ...
@mike-h With your Internal Diameter of 20.6 and flow of 22 you have a speed of 1.1 m/s. That will give you 6.27 kW of heat at dT 5. I will, at some ...
I wonder what CoP they are using and whether they are taking into account the future cost of the CO2 emitted. I suspect that there will be house/l...
You can wear more clothes or move your house to a warmer location 🤣 Yup, I did that already, and should have put in 35mm not 28mm (at least to th...
- 26 Forums
- 2,618 Topics
- 61.1 K Posts
- 829 Online
- 6,994 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Renewables & Heat Pumps in the News
@jamespa After all, they are ‘burying their mistakes’ -...
By Toodles , 18 minutes ago
-
@andrewj A ‘DIY’ job suggests you may clean up quite we...
By Toodles , 29 minutes ago
-
RE: Our 10 year old Grant heat pump failed
Back in the 70’s and through the eighties, one of my re...
By Toodles , 40 minutes ago
-
RE: Brown Oily Residue Blocking Air Vent and Weeping Relief Valve... Anyone Seen This?
Ouch thats leaking quite a lot! it looks like its easi...
By JamesPa , 4 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
@indevolt-uk Keen to know more about the pricing and wh...
By ChandyKris , 4 hours ago
-
RE: Share Your Experiences with Heat Pump Manufacturer Support
@seoras Sorry to hear that. I found Vaillant very help...
By JamesPa , 17 hours ago
-
The Watchdog That Watched and Waited
On 9 January 2026, Consumer Energy Solutions collapsed ...
By Mars , 20 hours ago
-
RE: GSHP Kaput After 16 Years: New Compressor or Switch to ASHP? Advice Welcome
Cool Energy in Grimsby sell ground source heat pumps an...
By DerekDeLeon , 21 hours ago
-
RE: Valliant Heat Pump Settings
Thats arguably a sign of a good installer - they unders...
By JamesPa , 22 hours ago
-
RE: Electricity price predictions
Well, we have so many cases where rain water mixes with...
By Batpred , 23 hours ago
-
RE: Two heating zones to one zone
@profzarkov They arent obviously wrong, but the only...
By JamesPa , 1 day ago
-
RE: Towns water feed to air source heat pump system
The DHW circuit cant be separated (well it could, you c...
By JamesPa , 1 day ago
-
Solis AC-coupled 3kW storage inverter
Solis AC-coupled 3kW storage inverterPylontech batterie...
By MartinRobinson , 1 day ago
-
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer
As @transparent has observed above, this is not bad, an...
By cathodeRay , 1 day ago
-
As I was reading this article Mars, I was thinking that...
By Toodles , 2 days ago
-
RE: Tell us about your Solar (PV) setup
Installed in May 2011: 16*Sharp 245 W monocrystalline p...
By txmartyn , 2 days ago
-
-
RE: Say hello and introduce yourself
That doesn't sound 'right' to me. The national Smart ...
By Transparent , 3 days ago
-
RE: Growatt battery disconnected
I doubt this will happen, but I will try and suggest it...
By Eliuccio , 3 days ago
-
Understood. That's why I decided from the outset on a ...
By JamesPa , 4 days ago
-
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
On the litigation, I would not go there and definitely ...
By Batpred , 4 days ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
I suppose if your pv inverter packs up, you have a plan...
By Batpred , 4 days ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
Firstly check you are using sound power not sound press...
By JamesPa , 4 days ago