Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 5, 2026
@iantelescope you cannot sort your control system out until you have sorted your hydraulic issues out and you are happy that it is running as efficien...
@jamespa You are absolutely correct and my point exactly. By using the correctly configured heat pump weather compensation you can match the h...
@iantelescope the honeywell thermostat was initially designed to control fossil fuel boilers but is compatible with heatpumps. If has the following ...
@derek-m @iantelescope You are almost correct. Option 2, the water pump is switched on and off by the room thermostat but continues running for 1...
@iantelescope I think Samsung intended this option to save energy however this should never be used especially when trying to achieve a continously ...
@iantelescope This #2091 option information is straight out of the Samsung user manual (which your installer should have left you a copy). I can cop...
@derek-m by applying 240v to the thermostat input terminal (which the honeywell does) then depending on which mode is selected in the Samsung controll...
postid="31563"] Disadvantages: The Thermostat minimum cycle time of twenty minutes, with a PWM Run time of between 3 and 8 minutes, the Grundfoss ...
As I have mentioned in a previous post, if you are in mode 3 field option #4091 if I remember correcly, you can increase the run time of the compresso...
@iantelescope I have managed to find a little wifi where I am. If you have the ability to isolate the buffer tank why not try this first? As @derek-...
@iantelescope Given the performance of your past installers, what are the reasons for concluding the PWM section of the Samsung board is faulty? ...
@derek-m I appreciate what you are saying and in an ideal world it would be best to remove everything and start again however I get the impression tha...
- 27 Forums
- 2,754 Topics
- 64.8 K Posts
- 1,504 Online
- 7,159 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
Thanks for sharing that. Your objective seems very sen...
By JamesPa , 1 hour ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles Very nice. Ours was the opposite, about 10%...
By Papahuhu , 2 hours ago
-
RE: Adding additional Solar Panels to a DC coupled battery system
A couple more points about placing solar panels at low ...
By Transparent , 3 hours ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@kilgorexv definitely a larger inverter will help and m...
By AndrewJ , 1 day ago
-
RE: Adventures in heat loss calculations
@rob-of-york — thanks for posting this, all very useful...
By cathodeRay , 1 day ago
-
RE: Surface mount or bury primaries for heat pump installation?
The installation is almost done! I've written up two ...
By tomasmcguinness , 2 days ago
-
RE: Glass lined Cylinder for private water supply
This has turned into a fascinating little rabbit hole. ...
By Mars , 2 days ago
-
RE: Switch suitable to change between two inverter CT's
Last winter my battery ,32KWh, could run the house com...
By Jancold , 2 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Agree with Major. And even if I was very happy with ...
By Batpred , 2 days ago
-
RE: Is the "divide by 2900" rule still valid?
There is another estimator that you could use, a formul...
By Rob of York , 2 days ago
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
@penval, really useful update. After all the discussion...
By Mars , 4 days ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 5 days ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 6 days ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 6 days ago