Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

SUNandAIR
SUNandAIR
@sunandair
Member
Honorable Member
Joined: Dec 30, 2022
Last seen: Mar 21, 2026
Topics: 5 / Replies: 564
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

@jamespa apologies James I’m on a train so dashing between platforms

1 year ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

@heatgeek I wouldn't normally comment on such a varied emitter scheme. I think I’m just trying to establish a few principles of HP operation in a simp...

1 year ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

My first thoughts are that the process is more dynamic than your model suggests. Your idea that demand is determined by the house isn’t quite how I se...

1 year ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

hi @jamespa Thanks for your reply. Thinking I can see a pretty good analogy and I will post it in the morning. 👍

1 year ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

Yes I think That’s quoted quite a lot if I’m getting your ratio of 3 correctly. The problem is, like all rule of thumb approximations is that that man...

1 year ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

Thanks for the nod James Hopefully my hand drawn “spreadsheets” are working now…. and the more detailed spreadsheet….. I hope the numbers are ...

1 year ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

Thanks for the official documentation info @transparent . I hadn’t read the most recent offering…. Is it me or does it really avoid tying anything dow...

1 year ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

not sure I agree… most of the sizing issues can be done at the design stage as a calc exercise. And as you and I have discussed previously… the design...

1 year ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

With due regard for the title of this topic… This debate has been brewing for quite a few weeks now. It certainly asks some questions of the standar...

1 year ago
Reply
RE: Ecodan 6kW - is it "cycling", or normal operation?

@clockworks while your sorting your wireless controller I have time to write a post on your rad capacity and the correct maths for sizing. So maybe l...

1 year ago
Reply
RE: Ecodan 6kW - is it "cycling", or normal operation?

Hi @clockworks Yes I sent you the charts which showed 3kw minimum output. I was very impressed when you managed to create the same hourly chart a...