Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 20, 2025
I've got the hidden registers being registered in two custom commands on boot of the ESP in my config here. I've put comments beside each register to ...
minimalmodbus requires full-fat Python, ESP can only run MicroPython. This snippet you've added doesn't touch Home Assistant so isn't a fair compariso...
Did you try it with something simple like DWH temperature first? I just added the code I pasted the other day and it changed the DWH temperature succe...
Use ESPHome Modbus Number or Switch components depending on what it is you want to do. For example setting the DHW temperature: number: - platf...
For the time being I've added a template sensor to calculate the approximate target flow temperature using y=mx+b. I added four number helpers into Ho...
I finally managed to get time to install the MIM-B19N modbus interface into my Samsung 8kw HT Quiet at the weekend. I'm integrating it with Home Assis...
@tomc are you adding a 120ohm resistor on the MIM-B19N between A+B terminals? I know Homely's install requires it and I see the USB adaptor you shared...
Hi! 🖐️ Just had our heating overhauled a couple of weeks ago, replacing an ancient Camray 5 oil boiler with an 8kW Samsung Mono HT Quiet (AE080BXYDEG)...
I just had the 8kW EHS Mono HT Quiet (AE080BXYDEG) installed and was about to order the WiFi kit before I found Glyn and @TomC's posts about modbus. ...
- 27 Forums
- 2,811 Topics
- 66.5 K Posts
- 2,170 Online
- 7,217 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@susannasaunders Reluctantly I think i agree with @r...
By JamesPa , 3 minutes ago
-
RE: Why don't people choose heat pumps?
It's swings and roundabouts - during off-peak periods t...
By Temperature_Gradient , 1 hour ago
-
RE: Adding data centre electricity costs to domestic energy bills?
never ceases to amaze me.. Keeping steel works going ...
By Batpred , 8 hours ago
-
RE: Electricity price predictions
great session Reminds me why some politicians can be ha...
By Batpred , 8 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Absolutely agree. The massive Hager CU my vaillant requ...
By Batpred , 9 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
absolutely agree. even if many providers see that extra...
By Batpred , 9 hours ago
-
RE: Octopussy cosy 6 experience
People who have a Cosy appear generally to be happy wit...
By JamesPa , 12 hours ago
-
I thought the cr*p came first and the biofuel came afte...
By Majordennisbloodnok , 16 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 2 days ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 4 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 4 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 4 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 5 days ago