@allyfish thanks for that. ”This is well known for both Li-Ion and Ni-Cad batteries.” Wish it was. Nothing about charge rate vs temperature in any...
@iancalderbank It's an interesting problem and far from straightforward. The risk reward balance is massively skewed towards not undercharging as that...
@iancalderbank Time-based improved in a software update last year - the one where you could enter the unit costs for the different time periods. Bef...
sorry for any confusion - it was the only reference I could find to charging and temperature! I don’t think you are alone @dunlorn there are two peo...
@dunlorn sorry really don’t know, temperature was just speculation on my part. The way I think it works is that the battery sends info to the invert...
Yes our Mitsubishi let’s us control the heating and hot water separately. That said we probably won’t turn the heating off - it is controlled by a w...
@davesoa don’t blame you. we don’t have gas and were about to need a new boiler and a new oil tank so went the ASHP route. it’s a massive fail by ...
@dandee 😀 Installation was ok. It was the commissioning that was terrible!
Batteries controllers may limit their charging current when they are cold - this could be a factor depending on where your batteries are located. A ...
A bit more... Last summer we ran in self powered mode - once the heat pump isn't heating the battery is plenty big enough to keep us going from day ...
The Powerwall has two modes - Time based control and self powered. Self powered mode will only charge from the sun - in summer that may be the righ...
Our Heat Pump installation went smoothly - 14kW Zubadan ASHP, conversion of HW system to mains pressure, new 250L tank, 18 radiators replaced - took l...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 92 Online
- 5,868 Members
Join Us!
Podcast Picks
Latest Posts
-
If you've never played (or heard of) Pirate Fluxx, then...
By Transparent , 26 minutes ago
-
@wully I have had my Eddi set by MyEnergi to minimise t...
By Toodles , 1 hour ago
-
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time
Doesn't the Joule preplumbed cylinder include a buffer?
By JamesPa , 2 hours ago
-
RE: Daikin 9kW to 8kW Swap Offer from Octopus
Not so. In my case it made the difference between 10.5...
By JamesPa , 5 hours ago
-
@bontwoody, I have to say, the response time here is re...
By Mars , 6 hours ago
-
RE: Renewables & Heat Pumps in the News
It rather depends on what we call 'local area' and 'tot...
By Transparent , 8 hours ago
-
RE: Mitsubishi Ecodan F8 error
Better than an early Windows/DOS error 'Faulty keyboard...
By JamesPa , 9 hours ago
-
I can now, I done an automation in Home Assist...
By DREI , 9 hours ago
-
RE: Bosch CS5800i 5kW - Experience So Far
What a difference a pump makes. We don't have OpenEne...
By Steelbadger , 10 hours ago
-
RE: Inventor (Midea) Heat Pump short cycling advice
I installed the 80L tank (volumizer) things got better ...
By immunity , 14 hours ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
@papahuhu at the end of the day if you are happy with h...
By benson , 1 day ago
-
RE: Can you recommend a Mitsubishi service engineer in the Rochdale area?
@dgclimatecontrol We'll all need annual servicing. How...
By Suzy-shadow , 1 day ago
-
RE: Octopus tariffs - a quick comparison
Does indeed need checking, @tim441. Neither Homely ...
By Majordennisbloodnok , 1 day ago
-
RE: How not to install a heat pump
Delighted to hear that the buffer has been replumbed as...
By JamesPa , 1 day ago
-
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
@davidnolan22 So far as I can tell from the 'other p...
By JamesPa , 1 day ago
-
RE: 5 Star Service from Havenwise
I keep getting havenwise ads on my Facebook feed, so cl...
By benson , 1 day ago
-
Automation options to maximuse efficiency & ToU tariffs
I started a conversation with ChatGPT. What automation...
By Tim441 , 2 days ago