Last seen: Nov 25, 2023
I suppose another incentive for A2A is in a move away from the central heating idea of heating all rooms that could conceivably be used during the day...
@mjr Ah yes, the 25kW boiler they installed in my 100 m2 home when the daily average power never exceeded 3kW during this recent cold snap. I d...
The performance of DFS was covered during a talk from ESO. The slides are here.
I'd add that air temperature is not the only determinant of thermal comfort in a room. A major component of the perception of cold is radiative loss ...
@alec-morrow A room and its contents has a given thermal content at given temperature. When it cools, it's because it loses heat to the exterior thro...
@cathoderay Wouldn't the extent of replacement depend on whether they are moving onto the original ASHPs or the new higher temperature ASHPs being rel...
I have participated in 3 of the Demand Flexibility tests run through E.On now, two of an hour each and one of two hours. The percentage reduction the...
@cathoderay There's some serious problem with the temp measurements. Touch will also readily distinguish temps around blood heat which is what your r...
@andris Not for Ovo. But the Octopus link I supplied earlier appears to suggest they look at your reduction relative to your average at those 2 hour ...
@andris Did you look at the link on "summary"? For example, with Ovo, they want you to reduce your energy consumed during the peak period to <12.5...
@derek-m If this is the constraint, there are two ways in which it can happen:, because the PHE heat transfer is limiting or secondary flow rate is li...
- 26 Forums
- 2,318 Topics
- 52 K Posts
- 141 Online
- 5,978 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Battery with existing PV - regulations
I am curious... which inverter would you go with for so...
By Batpred , 2 hours ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
A2A is really good. Simple. Cheap. Great success in oth...
By swwils , 3 hours ago
-
RE: Which 6kw to 8kw ASHP can modulate down the lowest ?
That’s one for the installers. @patrickvito @damon @ave...
By Mars , 3 hours ago
-
RE: 10kw heat pump run in 24*7 data?
Good little test tonight and tomorrow morning weather s...
By jeegnesh , 3 hours ago
-
RE: Replacing my 18 month old ASHP
@trebor12345, asked me to post this video for him which...
By Mars , 4 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@jamespa/p> Run starts at 11. It didn't do a defros...
By swwils , 6 hours ago
-
-
@sune would these work in a horizontal rather than a ve...
By Grantmethestrength , 8 hours ago
-
I had very helpful advice from several forum members ba...
By Steam Powered , 9 hours ago
-
RE: Battery storage to run Heat Pump.
That comment is welcome, but can be read in two differe...
By Transparent , 10 hours ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Oh the installed needs to go somewhere, that's...
By Crimson , 10 hours ago
-
RE: Who's your electricity provider and what's your tariff?
I can confirm a trend with EOn ... From compliance/ethi...
By Batpred , 14 hours ago
-
Given the underspent for the budget of the Solis invert...
By Batpred , 14 hours ago
-
ASHP Model: Daikin Altherma 3M 4KW House loss: Calcul...
By RadWhisperer , 16 hours ago
-
RE: Grant Aerona: Is there a setting to keep the 2-port valve open during pump blockade
Not unless either you allow the AI to turn on cooling w...
By JamesPa , 17 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
If you mean with Home Assistant, I have got a Solis mod...
By Batpred , 1 day ago
-
RE: Renewables & Heat Pumps in the News
Sorry I did write a reply to @jeff the other day and th...
By Lucia , 1 day ago
-
RE: Electricity price predictions
I expect to be addressing a meeting of residents living...
By Transparent , 1 day ago