Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Dec 18, 2025
The system was installed as a 3 zone system with programable thermostats in each zone. The zones were set up by the installer to turn on and off with ...
I have now implemented the WC curve/line in HA that @TomC shared, but I'm not sure if the heat pump is running efficiently with this setup? I...
Unfortunately I don't really have any experience of trying to control the unit with minimal modbus. The only thing I used on Linux was mbpoll to initi...
Thanks very much Ian, I changed FSV 2091 to "Not Use" but it didn't have any effect. I then also changed FSV 2092 External Thermostat Application #2 (...
@iancalderbank I have come back to this a number of times but always thought I was doing something wrong. My system was initially set up to use Water ...
@kocta This is my configuration.yaml code which is very much based on the work of others here # Samsung Heat Pump Modbus Connection modbus: - name...
I came across this video which is an interesting example of heat pump control within Home Assistant
I have added the UI config and the YAML config of the script here. The main part is "modbus.write_register" and the payload associated with that. As...
@derek-m I only heat the water twice a day (at the moment it's to 50 degrees from 02-05:00 during the cheap night rate and to 42 degrees from 15:45-16...
@derek-m I am on a variable tariff so I'm turning heating and hot water off from 17-19:00 and upping the hot water set temperature from 2-5:00 I'm u...
I meant to credit Glyn Hudson for the hidden registers PDF which I found on his GitHub page
I had converted the Samsung Modbus MIM-B19N section on registers from PDF into Excel just to make it a bit easier to understand for myself. The sectio...
- 27 Forums
- 2,541 Topics
- 59.2 K Posts
- 345 Online
- 6,822 Members
Join Us!
Worth Watching
Latest Posts
-
The corrosion problem was never resolved. I filed a law...
By phowardstutterheim , 1 hour ago
-
RE: Aerotherm 12+12kw cascade huge power utilisation
This is spot on. For all of MCS’s shortcomings, insta...
By Mars , 2 hours ago
-
@cathoderay I agree the baseline set is tricky and I ha...
By Judith , 3 hours ago
-
RE: Heat pump Surge protection
I’d love to get your input here @transparent… this is a...
By Mars , 3 hours ago
-
RE: NIBE Heat Pump Warranty: What's an Adequate Engineer Attendance Time?
@hughmark, great to hear. Fingers crossed that it’s sor...
By Mars , 3 hours ago
-
RE: Daikin high temperature heat pump
I’ll check in with Daikin to see if they can help answe...
By Mars , 3 hours ago
-
RE: Samsung Gen 7 16kW Integrated unit Modbus monitoring
@johnnyb HI,I have an integrated unit with all componen...
By antonical , 5 hours ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@papahuhu Ironical isn’t it? The last few days, the ‘Ag...
By Toodles , 7 hours ago
-
RE: Setback savings - fact or fiction?
I answered that days back, I even provided a summary of...
By RobS , 7 hours ago
-
RE: If a heat pump can only heat DHW to 50C then what? Issue with 18KW Heliotherm heat pump
I must say that this install is sounding more and more ...
By Mars , 11 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Thanks, that’s a fair point and I agree th...
By Eliuccio , 1 day ago
-
-
RE: The law of unintended consequences....
Oh Thank you Major, I was just beginning to wonder wher...
By Toodles , 2 days ago
-
RE: Forum updates, announcements & issues
I know that the notifications are being delivered now w...
By Mars , 2 days ago
-
RE: Advice needed after a successful "leftfield" experiment.....
@pauli I have sent a direct message with the financial ...
By ChandyKris , 2 days ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
Does it disappear when the heat pump is off? What abou...
By JamesPa , 3 days ago
-
RE: Fitting heat pump plumbing and pipes in advance?
Great tips, thanks. The PEX/Al/PEX option sounds much m...
By Jonatan , 3 days ago
-
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP
Those control valves on the UFH manifold could be an is...
By Travellingwave , 3 days ago
-
RE: Daikin Altherma 3 LT compressor longevity question
Up to a point yes. However every heat pump (and every ...
By JamesPa , 3 days ago
-
RE: New Build ASHP Defects - Looking for Advice, Support & Shared Experiences
Is that a single pair only? If so it may be part if th...
By JamesPa , 3 days ago
-
@batpred, you’re quite right; it does work well. I don’...
By Majordennisbloodnok , 3 days ago
-
RE: Ecodan Cylinder Possible Weeping Around Thermostat Port
Update: Mitsubishi sent an engineer around. It was li...
By Gruff2001 , 3 days ago
-
RE: A Smarter Smart Controller from Homely?
@benson Agreed. I believe the COP gains with homely, i...
By Papahuhu , 3 days ago
-
How to Find All Your Posts and Topics on the Forum – A Quick Guide
If you’ve ever posted something on the forum and then s...
By Mars , 4 days ago