Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Papahuhu
@papahuhu
Member
Reputable Member
Joined: Aug 4, 2025
Last seen: Apr 24, 2026
Topics: 7 / Replies: 245
Reply
RE: Solar Power Output – Let’s Compare Generation Figures

@transparent The AC output from the PW3 is 11.5kVA and input is upto 20kW of DC. I’ve heard of people getting approval for the full output, so I fe...

4 months ago
Reply
RE: Solar Power Output – Let’s Compare Generation Figures

@transparent 1P only. Wish I was on 3P, we have a long tarmac drive, didn’t want to dig it up. My G99 application was for 11kWh, they only gave m...

4 months ago
Reply
RE: Solar Power Output – Let’s Compare Generation Figures

@dr_dongle With panels so historically cheap don’t dismiss it. We are not as northerly as you but are at high elevation and have poor solar conditi...

4 months ago
Reply
RE: Solar Power Output – Let’s Compare Generation Figures

@profzarkov why can’t you use an s-bend on boat drains/toilets, or are they there and it’s just because they don’t have a high enough stink pipe/ tank...

4 months ago
Reply
RE: Solar Power Output – Let’s Compare Generation Figures

@profzarkov bet you don’t miss the constant aroma of the chemical toilet, although I otherwise love the idea of living on the water. We did a holid...

4 months ago
Reply
RE: Solar Power Output – Let’s Compare Generation Figures

@dr_dongle we put in a single PW3 and cycle the battery 3 times in 24 hrs. It’s a good, 10 year unlimited cycles warranty, so I figured if I flog i...

4 months ago
Reply
RE: Radiator sizing sanity check

@jamespa Thanks for the help. Yes, I’m going to push for significant upsizing of all cold room rads, about 8 of them. Probably at least 50% greater ou...

4 months ago
Reply
RE: Radiator sizing sanity check

@jamespa It was -7C here last night, the heat pump continued to behave exactly the same on/off, all it did was operate at an even higher output tha...

4 months ago
Reply
RE: Radiator sizing sanity check

@jamespa Thank you, I appreciate the advice. I have a couple of cards that should give me some leverage and some hope that I can persuade them to...

4 months ago
Reply
RE: Radiator sizing sanity check

@jamespa this afternoon I was told whom was being sub contracted to repeat my heat loss survey next week. When I checked him up he runs a plumbing ...

4 months ago
Reply
RE: Radiator sizing sanity check

They’ve had a while to settle down and both read nearly exactly the same, within 0.5C. Therefore you were right, they are providing anomalous result...

4 months ago
Reply
RE: Radiator sizing sanity check

@toodles thanks Toodles. That looks like the most probable explanation then. I’ve just taped mine on, I’ll give it an hour to let it all settle down, ...

4 months ago