Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 14, 2026
I have seen mentioned two things that may help alleviate the effects of defrost cycles. The first is having sufficiently large thermal mass within t...
I'm not sure I follow. I have a 12kW Samsung ASHP, and starting from cold, which we do most mornings as we often switch off overnight, the system norm...
I generated 6.4kWh on Saturday 2.8kWh on Sunday and 7.4kWh yesterday from my south facing 3.65kWp array - Saturday and yesterday were very good days w...
I'm running a 'flat' WL curve of 32C (32C @ 15C OAT; 32C @ -2C OAT), and I then manually adjust LWT up and down on the controller heating screen. At t...
I don't know how having two zones may complicate/affect things, especially as presumably the two zones may require different flow temps? With #2091-...
@cloudclear sounds like a good plan. I do not have any monitoring, so am simply collecting data and recording through studious observations. FSV #20...
I believe the guys above have nailed it. I have a similar 12kW Gen6 Samsung and observe exactly the same. The heat that the ASHP is producing has to...
That would be the more logical place to fit them, but ours is installed on the main return pipe back to the heat pump, so affects both DHW and heating...
@rhh2348 My system has a 50L volumiser fitted in the main 28mm return pipework, which at the end of the DWH cycle will also contain 50L of hot (55C) w...
This is exactly what I observe with my oversized Samsung when I run it in always on mode via the room stat calling for heat. If I set the WC curve t...
Optimising flow rate for DHW heating is something I'd been thinking about over the summer, as we are only heating DHW at that time. My simplistic th...
I don't I'm afraid - you could try looking up the specs of the Grundfos pumps online. My own system uses fixed flow rate Wilo pumps, with 3 differen...
- 27 Forums
- 2,794 Topics
- 66 K Posts
- 1,770 Online
- 7,196 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
How quickly would you want/expect heat recovery to take from setback?
Now into year 2 with my Cosy 9. I currently have it se...
By AndrewJ , 1 hour ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Not quite, regular A2W heat-pumps need a load of extra ...
By Temperature_Gradient , 13 hours ago
-
RE: Heat Geek installations: share your experiences
one thing i learnt from reading people’s comments and e...
By Batpred , 15 hours ago
-
RE: Cooling/heating with one unit
"The way we use A2A on a cheap overnight EV tariff is t...
By mrkfm , 17 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
We have ‘signed on the dotted line’ today for a Panason...
By Toodles , 18 hours ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
...or it was there and was lost thanks to laziness and ...
By Majordennisbloodnok , 18 hours ago
-
@bobflux Thank you for your response. I am trying to ...
By RonV. , 18 hours ago
-
This post is about how I successfully configured a buff...
By Tony.Stolz , 22 hours ago
-
The installer visited yesterday and suggested the noise...
By JamesChatz , 23 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Your house sounds a lot like mine. 2 surveyors each sp...
By JamesPa , 1 day ago
-
RE: Heat Geek Zero Disrupt: Are We Sleepwalking Into Another Race to the Bottom?
Thats true only if you do the wrong experiment. Done c...
By JamesPa , 1 day ago
-
RE: battery storage without solar
As of October 1st they need specific qualifications to ...
By EtchedPixels , 2 days ago
-
RE: Renewables & Heat Pumps in the News
With regards to the BUS grant raid, I gave it more thou...
By ASHP-BOBBA , 2 days ago
-
RE: Why are ASHP installs so expensive?
The whole system seems to work on the basis of...
By ian33a , 2 days ago