Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 5, 2026
Seems any pipework that is leaving the room is insulated so not sure if it would make a a noticeable difference to my bills to insulate the internal p...
Very happy with advice i got here on how to optimize my heat pump. I am finished altering settings as recently finished balancing the house to my liki...
@derek-m ahh OK. Yeah it's the condenser so luckily by the sounds of things.
@derek-m i have phe in my daikin. It seems to be always 0.1deg higher then lwt. Is that the efficiency issue? I'd imagine most daikin Have them as i...
@iancalderbank Yep mine is near 2 degrees colder when it's running according to reading on my unit. Noticed it few times.
Down to -6 last night. Yesterday running fixed flow@31 deg I used 29kwh for heating/dhw. Kitchen 22, othere areas 21/20. Running 9am-11pm. Very happy ...
I would like installers to balance system and work out curve with which lowest flow temp will keep house@21deg and not just go high flow temp to avoid...
Do you mean loop circuit lengths or just heatpump unit being close to manifold?
@derek-m Dont know, I presume i would have to had lowered ft to 28 which would also increase cycling, was cycling at 2 an hour from 7am to 9pm yesterd...
So as predicted i used near 22 (21.9kwh) for the 24hour period compared to just over 13 for the similar weather conditions the previous day, house was...
Happy enough with b scenario. major improvement on last winter. If i spend anymore time in heatpump room, ill be sleeping alone.
@jamespa dunno man, i tried lwt@27 and it cycled a lot as rwt gets up to23-25 easy enough. I get what you are saying but reckon the heatpump is restri...
- 27 Forums
- 2,792 Topics
- 66 K Posts
- 2,722 Online
- 7,196 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
The installer visited yesterday and suggested the noise...
By JamesChatz , 45 minutes ago
-
RE: Heat Geek installations: share your experiences
I struggled with this problem as well. An independent t...
By L8Again , 1 hour ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
I am not here to defend Heat geek or anyone else, but I...
By JamesPa , 1 hour ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Your house sounds a lot like mine. 2 surveyors each sp...
By JamesPa , 3 hours ago
-
RE: Heat Geek Zero Disrupt: Are We Sleepwalking Into Another Race to the Bottom?
Thats true only if you do the wrong experiment. Done c...
By JamesPa , 4 hours ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
@temperature_gradient Isn't that just describing a regu...
By Prunus , 4 hours ago
-
@etchedpixels I thought about that too, and between ...
By RonV. , 7 hours ago
-
RE: battery storage without solar
As of October 1st they need specific qualifications to ...
By EtchedPixels , 17 hours ago
-
RE: Renewables & Heat Pumps in the News
With regards to the BUS grant raid, I gave it more thou...
By ASHP-BOBBA , 18 hours ago
-
RE: Why are ASHP installs so expensive?
The whole system seems to work on the basis of...
By ian33a , 18 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
Good plan. If you can get half hourly meter readings a...
By JamesPa , 23 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
@editor Most certainly. The heat pump was an ideal s...
By Abernyte , 23 hours ago
-
RE: Does anyone have experience of a smart water meter?
Yep I caught our slow leak from a £100 bill rise 8)
By EtchedPixels , 24 hours ago
-
RE: Do You Need a Buffer Tank or Low Loss Header for Underfloor Heating in a Large Property?
@jamespa in some cases, failing the Turing test might b...
By GrahamF , 1 day ago