RE: ASHP options for my mum living in Cambridgeshire

Ah good to know @iancalderbank, thanks. I guess if I asked them then and signed in blood that I wouldn't bug them with break-glass requests for help (...

2 years ago
Reply
RE: ASHP options for my mum living in Cambridgeshire

Hi @iancalderbank when I look at the Homely website it says that 'Homely can be purchased by our Accredited Installers and is not sold directly to the...

2 years ago
Reply
RE: ASHP options for my mum living in Cambridgeshire

Thanks @toodles for the response. Yes, that's what I'm talking about - almost Thinking v1.0 is using the ASHP with the 3rd party stats, on-off, LWT an...

2 years ago
Reply
RE: ASHP options for my mum living in Cambridgeshire

Hi folks – I’ve been noodling on the issue of controllers and I think this thread might be on-topic. We have (brief recap) a 16kw Daikin Altherma HT A...

2 years ago
Topic
Reply
RE: Octopus export - standard fixed tariff is 15p

Hi @tim441 yes that tracker rate looks great, what a saving! No wonder there is a wait list! Using my April consumption this year, the Octopus stan...

3 years ago
Reply
RE: Octopus export - standard fixed tariff is 15p

Hi @tim441 thanks for the reply and info, great stuff. We also have a 16kW ASHP and 6.1kWp of solar, UFH etc in a 300 sq m property - but no batteries...

3 years ago
Reply
RE: Octopus export - standard fixed tariff is 15p

@tim441 thanks for posting this - very interesting. I'm an expat living Italy and I'd be interested to know what additional charges appear on a UK bil...

3 years ago
Reply
RE: Hot water tanks with inbuilt ASHP !

Hi - I also came across these recently. I'm in Italy and someone on an Italian forum similar to this one said he'd installed one in the en suite bathr...

3 years ago
Reply
RE: ASHP choice help - 55C flow temperature required

...also this set of figures - same kit!

3 years ago
Reply
RE: ASHP choice help - 55C flow temperature required

@wintergreen here's what I have - apologies if it's too small to read. I was left two sheets by the installers - with completely different COP figures...

3 years ago
Reply
RE: Turning your heat pump off

My Daikin wall programmer has a button that allows you to switch on or off the space heating independently of hot water; both are separately programma...

3 years ago