Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Kev M
@kev-m
Member
Noble Member
Joined: Mar 5, 2021
Last seen: Jan 8, 2025
Topics: 10 / Replies: 1266
Reply
RE: Rule change re ASHP

I was hoping it would be part of a well thought, holistic review of the PD rules to make the planned HP roll out easier and not a knee jerk isolated r...

2 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

Interesting to compare the same time for mine. One thing that stands out is that your flow temps drop a lot further than mine during the setback.

2 years ago
Reply
RE: Rule change re ASHP

I managed to read it before the paywall went up. As far as I can see it is as it seems.

2 years ago
Reply
RE: Ecodan Room Temperature Mode

Yes that's the one. It's bit fiddly but worth persevering with. I agree about AA overheating but now Mrs M has got used to 22 deg I'm not going to ge...

2 years ago
Reply
RE: Ecodan Room Temperature Mode

@Sliderule, My house thermostats are still connected to the FTC but turned up high and the external pumps definitely don't run all the time. If ...

2 years ago
Reply
RE: Ecodan Room Temperature Mode

@sliderule, I left my thermostats connected but turned up high so they are always calling for heat. I use the wireless remote to run AA. It doesn'...

2 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

I haven't tried to work it out but I would have thought the OAT variation over the compared periods makes a big difference. It's a little bit unreali...

2 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

I used to do a bit of sql and other programming so I'm reasonably familiar. It's been a while though but I'll have a go. Feel free to tinker with ...

2 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

I can. What you are seeing is cycling caused by IAT. It's reaching its set point, or, because AA allows it, up to 1.5 deg above it. It then stops ca...

2 years ago
Reply
RE: Ecodan controller- one question and one observation

If you look on the front case of the FTC there is a model number. FTC6 is PAC-IF073-BE, FTC5 is PAC-IF063-BE. Lower FTCs have lower IF0X. Not sure ...

2 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

Life has got in the way a bit but I'm going to pull together some proper data to correspond with the charts I produce. The current issue is that the M...

2 years ago
Reply
RE: Mitsubishi Ecodan pipe width query

15mm primary flow pipes will definitely cause problems. There is a minimum flow rate depending on the size of the ASHP and it's unlikely that 15mm pi...

2 years ago