Sam I am sorry the ASHP did not work out for you. I’m only 3 weeks into mine, so don’t have any of your experience. But as Phil says, gas boilers wi...
Thanks Derek, always reliable information from you. So a hydro box is different from a split system. I’ve a split Daikin system with the fan, heat exc...
Hi Kuba I think it’s all about getting several quotes and approaches. 8mm pipes are small to the radiators, but do they run all the way back to the ...
Wow Jet, that is a large kW usage. A few questions as you property is a similar size to mine. And I have a HT ASHP. What was the original MCS heat req...
Phil, by small bore pipes to the radiators, in my case I mean 10mm. We have large “mains” pipes running in the loft that are 35mm or 28mm with 10mm dr...
Evening Phil. Get several quotes. They will need to do a heat loss and heat demand calculation. Your dimensions and oil usage were similar to my bunga...
DanT - we have 4kW of solar PV - we generate about 3700kWh per year - as you say much more in the summer. My system is 9 years old (see detailed desc...
Welcome Phil. Top tip is to speak to several ASHP installers to get a variety of views. Unless it’s the size of Blenheim Place, a 2005 built home shou...
DanT you definitely need to get a diverter. You look like a “data man”, so perhaps the Solic is not for you, but I can certainly recommend it.
Morning Dan T You are collecting a lot more data than I am. But I think your plan to only heat when needed is sound. Else the ASHP only heats a bit,...
That’s a whole lot of expansion vessels - 3? I’ve got one for the Mixergy tank. And the Daikin has an internal one
Good spot Kev M. Aj, what is the room by room heat demand / loss calculation? As Kev M says, changing every radiator is surprising. Can you do work t...
- 26 Forums
- 2,112 Topics
- 46.4 K Posts
- 55 Online
- 3,405 Members
Join Us!
Latest Posts
-
RE: Wood burner with ASHP - direct air?
@sune is ideal to answer this, but I think he's on vaca...
By Mars , 3 hours ago
-
RE: Say hello and introduce yourself
Hi @topher - you might be interested to see this very r...
By Transparent , 3 hours ago
-
RE: No-code, plug-and-play monitoring for your heat pump
We've got a svenar heat pump controller en route and lo...
By benson , 1 day ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Ebac 5kw - Monobloc R32. Developed and made in UK - Mit...
By marcinwloch69@gmail.com , 1 day ago
-
RE: Is a Valliant Inline 6kW heater a BUS buster?
Just another thought - it might be worth thinking about...
By JamesPa , 1 day ago
-
RE: BUS Grant: removal of all other fossil fuel heat sources
@rikiarn - just have a think as to how much it will cos...
By Transparent , 2 days ago
-
Don't do much digging around.That's best left to the pr...
By Transparent , 2 days ago
-
Hi all, I was wondering if anyone had an idea of how th...
By Wh0am3ye , 2 days ago
-
RE: EBAC re-entering the ASHP market in 2023
@toodles confirm i have Ebac 5kw ASAP + homely and it w...
By marcinwloch69@gmail.com , 2 days ago
-
RE: Compute heat loss from energy used
@jamespa Ebac must be similar to Mitsubishi as they buy...
By marcinwloch69@gmail.com , 2 days ago
-
@pie_eater I have been thinking of adding cooling to my...
By TechnoGeek , 4 days ago
-
RE: Victorian Semi Retrofit / Extension ASHP and UFH Advice
Agree, but you may have a hard time convincing them, as...
By JamesPa , 5 days ago
-
RE: Seal the Deal: Don't Let Your Heat Pump Leak Energy
Hi - fyi - there's a dead image link in the 'Optimal In...
By seatonian , 6 days ago
-
RE: Ripped Off: How UK Homeowners Are Paying Gas Prices for Wind Energy
@chandykris Horses and beggars…. 😉 Toodles.
By Toodles , 6 days ago
-
RE: Cleaning up after gas meter removed
@agentgeorge Likewise in the loft space; we have 300mm ...
By Toodles , 6 days ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
This particular example is one of the worst I have seen...
By JamesPa , 6 days ago
-
-
RE: Fan running in hot weather ...why?
I wonder if it has some kind of pressure transducer to ...
By ASHP-BOBBA , 1 week ago
-
RE: Cooling with Samsung Gen6 and Flow error
@iaack The system isnt running long enough for any cond...
By EcoBaker , 1 week ago