Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 13, 2026
You could try under kitchen unit coils such as/p> We have a 1kW version in the kitchen and if the oven has not been on in very cold weather then we ...
@cathoderay I agree the baseline set is tricky and I hadn’t followed the other thread because I couldn’t contribute much. Off-topic subject closed?
From my informal discussions with friends new builds can be worse set up than retrofit, since the plumber used by the builder knows less than average....
Repeating the figure for clarity The sampling is only every 5 mins so the accuracy isn’t wonderful. But I would contend that the overshoot (in term...
@morgan @old_scientist i agree that a COP of 4 is achievable at this time of year. The figure for the full week for us is 5.0 but I think it’s ~5% ...
In June 2025 this academic group at Oxford modelled the impact on supply of LNG and hence price of closing the Strait of Hormuz. Their conclusion pric...
@editor yesterday we used 12kW of electricity for heat, so a cost@15p per kWh of £1.80. It makes me (and the cat) purr, keeping the house warm. Som...
@expatingermany your pump sounds a bit like my Mum’s (gas) system when there was air in it. You might get some relief by bleeding the highest radiator...
I totally agree with the recommendations from Mars and James. Perhaps our example might help. We had quotes for mostly an ashp of above 12kW, becaus...
Ben Watts posted this analysis on LinkedIn showing the low overnight use is very much still prevalent, both over the last few years and in all region...
@martinrobinson & @davidb confirmed turning legionnaires cycle off via installers menu on control box DOES work, we put it off when we have visito...
@ch_18 downfield is completely correct but you should insulate your pipework as a first task. You must have an unnecessarily warm plant room at presen...
- 27 Forums
- 2,767 Topics
- 65.1 K Posts
- 1,553 Online
- 7,169 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
I can't help with your principal question but as a matt...
By JamesPa , 2 hours ago
-
RE: Siting of the external sensor on a heatpump
My heat pump receives sunlight, so when the fan is not ...
By bobflux , 6 hours ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
You should (almost) always reject having a buffer, by w...
By JamesPa , 21 hours ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 1 day ago
-
RE: Is it the house or the equipment?
@majordennisbloodnok I do sympathise. On the original...
By springswood , 1 day ago
-
No, but the heat pump must be capable of delivering a S...
By JamesPa , 1 day ago
-
Sorry to hear about the problems, its going to be somet...
By JamesPa , 1 day ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 2 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 2 days ago
-
RE: Vaillant Arotherm Plus 7KW need a service on it
booked it with Vaillant. will use them until i can find...
By AdamK , 2 days ago
-
RE: Adventures in heat loss calculations
I have seen it stated that the declared calorific value...
By JamesPa , 2 days ago
-
RE: Two heating zones to one zone
@transparent Many thanks. The garage is fairly well ...
By Profzarkov , 3 days ago
-
RE: Vaillant Aurotherm - Heater Wire Position
Ah, good point. I need to check if this was installed i...
By Batpred , 3 days ago
-
@batpred thanks for getting a copy. Appreciate the supp...
By Mars , 4 days ago