Activity
 
Notifications
Clear all
Jancold
Jancold
@jancold
Member
Reputable Member
Joined: Dec 16, 2022
Last seen: Nov 1, 2025
Topics: 6 / Replies: 141
Reply
RE: Three pipe buffer

@editor Looking at some of the changes to Part L this at the end of 5.20 this had me perplexed. NOTE: There is no need to install thermostatic room ...

9 months ago
Reply
RE: Three pipe buffer

Update. The system was fitted and commissioned last week, by Friday the radiator zone was still not coming to temp. On Wednesday we had a meet with th...

9 months ago
Reply
RE: Three pipe buffer

@jamespa Sadly the answer to why a buffer tank was, I've been working with Heat pumps for 47 years and we know this works. The club has 14 showers t...

10 months ago
Topic
10 months ago
Replies: 11
Views: 1227
Reply
RE: R290 install location and future of R32

@andrewj I understand there are R290 ice makers allowed indoors! Ok less R290 ( I believe Heat pumps have just over a kilo of R290). In my case it was...

10 months ago
Reply
RE: Battery sizing - How low can you go!

@transparent This business of SOC readout with Lipo4 batteries is so unhelpful. My boat setup has a Victron 200Ah battery which, when in commission is...

10 months ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

So this is their reply. "I have identified that a Removal of a Looped Service is required and potentially a Cut Out Change.This may require some...

11 months ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

@transparent So good so far I have completed the form and got my reference.

11 months ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

@transparent So does the NGED need to do this Upgrade before the Heat pump and smart meter install? The meter is mid January and the Pump late March.

11 months ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

This gets more interesting/ baffling. It appears the supply was reversed some time ago. There is no connection to the care home pole now. The cable su...

11 months ago
Reply
RE: Fitting emitters with output greater than room heat loss.

I have adjusted the output of all the proposed Radiator changes both mine and Octopus down to delta 25 and the output exceeds the Room loss by 60W to ...

11 months ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

@transparent Sometimes I feel I am thinking myself into a hole in the ground (Jim Henson, Storyteller). The incoming cable is marked OF 462-467, I c...

11 months ago
Page 4 / 13
Share:

Join Us!

Latest Posts

Click to access the login or register cheese
x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
ShieldPRO