Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 9, 2026
Topics: 27 / Replies: 5220
Reply
RE: Setback savings - fact or fiction?

FWIW the ramp with my Vaillant up occurs shortly after the cloud of vapour appears, so its during the 'recovery' phase. I have always assumed that th...

6 months ago
Reply
RE: Best temperature wave form for best economy and efficiency .

Agreed Agreed, an essential part of setting up a WC curve correctly I don't agree with this unless you want your rooms to be at 16. Assumin...

6 months ago
Reply
RE: Volumiser required on Grant R290 air source heat pump?

There is a thread from a year ago where this was debated at length and the conclusion, well argued imho, was flow is better but it's likely only to ma...

6 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

Yes it does, but you can disable it. Sensocomfort-Settings-Installer Level-Installation Configuration-Circuit 1-Room temp mod. Set to inactive to ru...

6 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

Check them. Filters, particularly the fine mesh filter if you have one (it may be inside the case) block up quickly. Mine blocked up to the point th...

6 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

Thanks for the info. Volumiser configuration should be OK, a little concerned the rads are original it suggests some may be undersized. OK, difficu...

6 months ago
Reply
RE: If a heat pump can only heat DHW to 50C then what?

As you now have a Heliotherm engineer on the case I wont comment further. As @mars says this is high end stuff, the suppliers need to be made to work...

6 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

OK. Well in case you haven't already the first thing to do is to disable all room influence and turn the WC curve down as far as you can until the ho...

6 months ago
Reply
RE: Same Heat Pump Size, Different Sized Homes: Would One Be More Efficient?

The larger house might turn out slightly more efficient due to increased system volume, but I'm basically on the same page as @majordennisbloodnok.

6 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

@davidb I'm presuming you are already running open loop 24*7, no external controls and have turned the weather curve down as far as possible consis...

6 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

@f1p OK noted Without further information about the system I cant really comment with any certainty, all I can do is cite generic statements ...

6 months ago