@damon thank you for posting. Would you care to tell us in what circumstances you fit a buffer tank, why, and how you set it up to avoid a cop penal...
... but a volumiser would prolong run times by the same amount without any of the downside risk in performance, difficulties with fault diagnosis and ...
This is indeed welcome news. In addition the new legislation: Increases the maximum volume under pd to 1.5cu m other than for flats where it remai...
That's my point really, it should be both freely and readily available. As you say it's just a table (or set of graphs) of cop and output vs ft and o...
Good luck, I hope it all works out!
In fairness to heat pump manufacturers the output inevitably (unless artificially restricted in software) varies with oat and FT. Furthermore the vari...
Thanks for the detailed reply and I apologise if I can sometimes be pedantic and determined to 'get to the bottom' of product claims. My aim is simply...
Really delighted to hear that. I can't comment on homely but if you don't have it then you will likely want to readjust your weather compensation cur...
Work on 2-3 percent per degree. This is a reasonable estimate of the reduction in COP because you will need to run the heat pump at a higher tempera...
The useful bit is the bit that specifies the heat loss at the design temp ( presumably around -3). It's your choice of course but I genuinely fear t...
@harryrea In a heat pump only system you are never heating space and DHW simultaneously because they require different flow temperatures. For the sam...
- 26 Forums
- 2,265 Topics
- 50.6 K Posts
- 683 Online
- 5,924 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
11.2kW Ecodan Manufacturer: Misubishi Model: PUZ-WM...
By DRB01 , 8 minutes ago
-
RE: Electricity price predictions
Do you have evidence that our level of bureaucracy/inco...
By JamesPa , 2 hours ago
-
RE: Midea ASHP – how to set weather compensation
@pash44pump - oh dear, it looks like they've managed to...
By cathodeRay , 2 hours ago
-
RE: Homely asking about Solar Panels.
@majordennisbloodnok I will report back with any develo...
By Toodles , 3 hours ago
-
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
Are you able to post a photo of that 180-litre cylinder...
By Transparent , 7 hours ago
-
Agreed. It doesn't take all that much maintenance to ke...
By Majordennisbloodnok , 9 hours ago
-
RE: Oil Boiler & Heat Pump Hybrid System
OK. Got it. As a fellow rural West Country resident, ...
By Transparent , 10 hours ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
@crimson I asked Eskimo about their correction facto...
By JamesPa , 11 hours ago
-
RE: My DIY Heat Pump installation
@pollar-bear Top job, I installed my own too and even t...
By bontwoody , 11 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
There are two definitions of sufficient volume. The fi...
By JamesPa , 11 hours ago
-
RE: Who has a V2G EV installation
Not sure how you got that information, @batpred. As of ...
By Majordennisbloodnok , 11 hours ago
-
RE: UFH downstairs and radiators upstairs balancing question
@ashp-bobba Can I pick you brain about mine ...
By davidnolan22 , 13 hours ago
-
RE: Flexi-Orb Heat Pump Scheme: A Game-Changer for the UK's Heat Pump Industry
Ok so that seems to be the key point namely only mcs ca...
By JamesPa , 1 day ago
-
RE: One flow valve appears to be duff
You might want to consider the following common faults:...
By IaAck , 1 day ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
We are on the Intelligent Octopus Go tariff. We instal...
By GrahamF , 1 day ago
-
RE: New build installation query
@paullacey While the others wait for more info do you m...
By ASHP-BOBBA , 2 days ago
-
RE: British Gas Heat Pump Installation Complaint
@bgno, the other consideration for legionella cycles ar...
By Mars , 2 days ago