Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 28, 2026
Topics: 28 / Replies: 5535
Reply
RE: Cooling with air to water heat pumps

Passive cooling should always be the first call. Keep the heat out rather than trying to extract it by using more heat! Southern European countries ...

2 months ago
Reply
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless

It can be done but really, really, don't, you will regret it and you will suffer exactly the problems your installer is predicting and almost certainl...

2 months ago
Reply
RE: How Accurate Is My DIY Heat Loss Calculation?

I think this calculation goes the other way. 3.54kW gas is used of which 85% went to the house (the rest up the flue). So the house needed 3kW. ...

2 months ago
Reply
RE: Volumisers in Heat Pump Systems: Does Placement Matter?

Volumisers are normally plumbed so that they are in the heating circuit only, which is done by putting them after the diverter valve. Yours has obvi...

2 months ago
Reply
RE: Plug and play solar. Thoughts?

My thought is simple. Bring it on and bring on plug in batteries asap as well. I think that the g98 position may mean that you can still have 1 p...

2 months ago
Reply
RE: Heat loss calculations

That's consistent with your heat loss calculation. You will end up with a 5 or 6kW heat pump. Cosy 6 if you go with octopus, probably the Vaillant ...

2 months ago
Reply
RE: Heat loss calculations

Good exercise. Obviously I have nothing to check it against but its very plausible. Do you have your current fuel consumption as a sense check? At...

2 months ago
Reply
RE: Heat Geek mini store vs pump size

When looking at 3-4kW houses its also worth bearing in mind that most manufacturers dont sell anything smaller than 5kW (sometimes they sell a heat pu...

2 months ago
Reply
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?

@majordennisbloodnok @tomtheheatingengineer For my money both Heat Geek and Octopus have the advantage of volume. This provides them with real da...

2 months ago
Reply
RE: Do I add Air Con or MVHR to existing A2W ASHP?

There is scope for product development here. I for one don't want another ODU and another set of pipework around the house, even to just the two or t...

2 months ago
Reply
RE: Do I add Air Con or MVHR to existing A2W ASHP?

Nought for nought is the very best you can do, as soon as you try to get anything at all you get less because entropy continually increases. This is...

2 months ago
Reply
RE: Is the "divide by 2900" rule still valid?

Really flow rate is a pipework limitation not a water pump limitation, you can always fit a pump with a greater head or a supplementary pump, but ther...

2 months ago