Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 10, 2026
It does feel like you may have a genuine fault, unfortunately perhaps not bad enough to convince the manufacturer easily. Id be tempted to collect ...
All understood. Basically you are planning on creating a recirculating loop. There are a couple of threads running about this with people complaini...
The last bit of that is bad. Thats just badly (well appallingly) designed UFH and most likely the fundamental problem here - half your energy is goin...
Unfortunately COP for DHW will always be lower because it requires a higher flow temp and thats how the thermodynamics work. 52C is high however, you...
Er not sure that is universally true. Mine is cheaper overall to run that my gas boiler would have been, by about 20% or thereabouts. I have radiato...
Firstly you are getting your units mixed up which is a little confusing. kW is power (how fast you are driving), kWh is energy (how far you have gone...
I would bypass the buffer tank in one of flow or return only, it will then act a bit like a volumiser. The problem you have relatively to a tank th...
I agree with all of that. 220 pages is perhaps 210-215 pages too much. Unfortunately there is no substitute for (a) understanding some basics (which...
@davidnolan22 Perhaps you could post some more info about your setup, house and system and WC parameters - you never know it may be possible to diag...
OK. I have 2.8 for DHW and 3.4 for space heating running at an actual FT of about 36. Yours does seem a bit low depending on what FT you were runnin...
Don't forget to increase max ft also. Mine is set to 55, way clear of the curve. I think that might even have been the default.
Suggest, as a test, you turn up the WC curve a lot so any change or not is unambiguous. I'd also set max ft to say 55 to get this parameter out of th...
- 27 Forums
- 2,787 Topics
- 65.8 K Posts
- 1,181 Online
- 7,192 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: PV and battery long payback - sense check query
@energystoragetech it's highly improbable that @davidb ...
By Transparent , 44 minutes ago
-
RE: Heat Geek installations: share your experiences
@editor I suspect that the Heat Geek online quote is a ...
By AndrewJ , 51 minutes ago
-
RE: tepeo ZEB UK Support & Info Thread
@toodles The tepeo ZEB is a residential heat battery, w...
By wully , 59 minutes ago
-
RE: Adding additional Solar Panels to a DC coupled battery system
Ah, yes. Thanks for clarifying.
By Transparent , 1 hour ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
Ah, that explains it. Thanks! Then I agree with ot...
By cathodeRay , 3 hours ago
-
RE: Home energy storage & battery register
A useful register should record model, usable kWh, inve...
By EnergyStorageTech , 7 hours ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
@trebor12345 I have been meaning to get home assista...
By Batpred , 12 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
SunSynk hybrid inverters also have the capability to as...
By Transparent , 15 hours ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
If you've got a sash window or a door you can remove th...
By EtchedPixels , 16 hours ago
-
RE: Heat Geek Zero Disrupt: Are We Sleepwalking Into Another Race to the Bottom?
Roughly how most air/air is done except that step 3 doe...
By EtchedPixels , 16 hours ago
-
RE: Nook batteries from Octopus
@batpred If your energy use is low enough that just get...
By EtchedPixels , 16 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
I suspect 4 yrs ago, their approach had not got to this...
By Batpred , 17 hours ago
-
RE: battery storage without solar
Also don't forget that in you may not be able to use th...
By JamesPa , 1 day ago
-
RE: Tesla Powerwall (2) Calibration Cycles
One practical safeguard is to separate the calibration ...
By EnergyStorageTech , 1 day ago