Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 14, 2025
@sunandair DT is a phrase used too much in HP discussions, one needs to be clear about between what points the difference is being measured. Its nor...
doesn't matter. check the datasheet 2 posts up. the higher the flowT, the worse the COP. same for any heat pump. also you are talking about loss...
@sunandair if your sketch is accurate, and the DT on both sides is the same, and the flow rate on both sides is the same, then heat energy transfer is...
kwh needed is the only unit that can be calculated or estimated by a system designer. although we've had a lot of debate here about how accurate (or n...
@amanda1 several of us are trying to politely put you on the right track, there is no misogyny here, I think I was quite polite in my previous posts. ...
@amanda1 from what I can see (From a quick read of their manuals), the mitsubishi "freeze stat" configuration is a form of "freeze protection function...
@amanda1 in general there are a few concepts to try to separate and think about "defrost" = the heat pump running in reverse. to defrost itself w...
here's a use case: I've seen the "freeze protection mode" on my (samsung) kick in during a very cold snap night in april, after a mild day. the heatin...
@derek-m mine is the same type of system as tim's. here's snapshot of one of my panels just now (its not sunny). current is more or less the sam...
@amanda1 in general, the purpose of the anti-freeze protection function of the HP is usually for the "AND" situation: "outside air temperature below ...
@allyfish mm ok, there must be something else making it cut out because you should be able to go as hot as the immersions limiter, maybe grant have d...
@allyfish at this time of the year if you have copious PV you can turn the immersion stat up to maximum thereby dump the max amount of free energy int...
- 27 Forums
- 2,796 Topics
- 66.1 K Posts
- 2,675 Online
- 7,199 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
My heating has been off and DHW on throughout the summe...
By DavidAlgarve , 20 minutes ago
-
RE: Anyone concerned about GivEnergy?
The GivE forum seemed to have survived the collapse of ...
By downfield , 1 hour ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
@singlespeed I had better explain how my radiators are ...
By Toodles , 2 hours ago
-
RE: Cooling/heating with one unit
@mrkfm The Solo has a small capacity and only suitable ...
By dgclimatecontrol , 2 hours ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
Firstly you have come to the right place and its good t...
By JamesPa , 2 hours ago
-
RE: Renewables & Heat Pumps in the News
The irony is there's already an established internation...
By Temperature_Gradient , 4 hours ago
-
First you need to know how much thermal energy you'll n...
By bobflux , 14 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
Come for the low-carbon homes. Stay for George Clarke’s...
By Mars , 2 days ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@razz, as we head into the heating season, I just wante...
By Mars , 2 days ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Not quite, regular A2W heat-pumps need a load of extra ...
By Temperature_Gradient , 4 days ago
-
RE: Heat Geek installations: share your experiences
one thing i learnt from reading people’s comments and e...
By Batpred , 4 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
We have ‘signed on the dotted line’ today for a Panason...
By Toodles , 4 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
...or it was there and was lost thanks to laziness and ...
By Majordennisbloodnok , 4 days ago
-
Bufferless design & control of Chinese air to water monoblock hybrid heat pump in Alberta, Canada
This post is about how I successfully configured a buff...
By Tony.Stolz , 4 days ago