Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 27, 2025
Remove the llh and the secondary pump, wire the pwm line of the primary pump up to the Samsung controller…. That’s pretty much all there is to it.
@derek-m The carel controller in my ASHP allows me to specify three pump modes: Normal, Demand, Continuous... Normal - pump shuts off when setpoint...
Heat pumps and thermal stores are bad news, really really bad news.... Who designed this system?
Indeed.... And I wasn't too happy that I couldn't see the product before buying it, hence why I went with Cool Energy. I saw them at Installer show an...
Quote attached…
I asked Acond for a quote back at the start of my ashp journey… I nearly fell off my chair when the email came in…
@elton the issue is purely energy costs…. When people say ‘my heat pump doesn’t work’ what they really mean is ‘it costs more than the gas boiler did’...
None of this would matter if electricity wasn’t 3 times the price of gas. Rebalance the energy prices and you can get away with sub optimal installs w...
Alec hit the nail on the head right there I think. Most heat pump controls are a bit pants, or a cryptic to use (that’s why GH is always championing t...
The secondary pump won’t be pwm controlled, I assume? Why do you have a buffer and secondary pump anyway?
That’s a daikin hybrid system which uses an intergas boiler as the gas fired bit. looks like it’s firing at 31 degrees flow temp, which is probably ...
25-27th June at the NEC.
- 27 Forums
- 2,733 Topics
- 64.2 K Posts
- 1,387 Online
- 7,139 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Questions about A2A for heating as well as cooling
Thank you for that very helpful and thorough response! ...
By donciccio , 4 hours ago
-
RE: Aircon - in listed buildings
@etchedpixels thanks for giving such a full and helpful...
By GrahamF , 18 hours ago
-
RE: Acond heat pump failed after four years - diagnostic quote £940 plus VAT
Another idea if the above don't work - there are compan...
By downfield , 20 hours ago
-
RE: Love veg, hate watering cans
They have their downsides but boreholes are great in th...
By ian33a , 21 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist The service engineer powered down the ex...
By Papahuhu , 22 hours ago
-
RE: Issue with Samsung Cascade System
@jamespa It's a funny system, but was out only option l...
By Renewables345 , 1 day ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Thanks, I like the chart, very helpful and this will de...
By baroquebank , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Production resumed to normal once the issue ...
By MK4 , 2 days ago
-
RE: Digest of UK Energy Statistics
That sounds painful. It would be much better to charg...
By Transparent , 3 days ago
-
Hole diameter is small but hole length is also very sma...
By bobflux , 3 days ago
-
RE: Are Wind Turbines Really “Losers”?
We were sailing near a wind farm in the North Sea last ...
By Jeff , 3 days ago
-
@trebor12345 The idea is to ensure that Powerwall knows...
By Toodles , 3 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
'hard limited' could be in 'admin' password protected s...
By JamesPa , 4 days ago