Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 27, 2025
@marvinator80 Bigger radiators, better insulation, or higher flow temperature - pick your poison...
New bms delivered today from fogstar, all installed and up and running 👍 Now to find that 3kW charger I’ve got somewhere….
Don't worry too much about deltaT across radiator flow/return - my system runs at about 2-4 degrees. House is nice and warm, everything works...
@transparent The seplos v3 is the standard passive balancing BMS, their 'active balancer' is a separate unit that connects via an additional harness, ...
@makia2023 I hooked up the cell monitoring lines before connecting the B+ cable (circled red) from the pack to the BMS. After about 2 mins I noticed t...
Just an FYI, yes you can easily assemble the 280L when in vertical mode. Blown up the BMS so I’ll need to sort another one, but I’ve got this far. W...
It did appear to be cheaper, yes. Ideally I'll have something up and running before xmas, but it's not the end of the world if I don't. I've got until...
@transparent I've ordered a 1S LFP charger from ali, 25a, so that gives me a bit more power compared to my bench PSUs at work. I need to get my Eltek ...
@transparent I've got plenty of bench PSUs available at work, but the plan at the moment is to follow the instructions on the diy solar forum. Throw i...
@transparent I'm offgrid and currently charge my Diy'd 9.6kWh pack from my inverter/charger/mppt. I don't want to decommission this setup until the Ma...
Picking error at the warehouse apparently - Fogstar delivering the correct accessory pack tomorrow. As for the active balancer - youtube research su...
I've sent an email with my queries to fogstar support who I purchased the whole kit from. In the meantime I will continue to assemble the kit as far a...
- 27 Forums
- 2,810 Topics
- 66.4 K Posts
- 3,655 Online
- 7,216 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Electricity price predictions
I wasnt sure where to post An interesting meeting ...
By Jeff , 12 hours ago
-
RE: Why don't people choose heat pumps?
Again, spot on. The problem is that we in the UK have d...
By cathodeRay , 12 hours ago
-
RE: Adding data centre electricity costs to domestic energy bills?
I should say my points are simply raised to test the fo...
By Jeff , 13 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Agree with everything else. Personally I think the as...
By JamesPa , 19 hours ago
-
There's a company called Xlinks who are proposing just ...
By Transparent , 21 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 23 hours ago
-
RE: Octopussy cosy 6 experience
@paultheheating Unless things have changed more recentl...
By Toodles , 2 days ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 2 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 3 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 3 days ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@etchedpixels Agreed, just a thought for others. I am...
By Watcher , 4 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 4 days ago
-
Coming back on subject... A shortened version of the ...
By Transparent , 5 days ago


