As I said in a previous post your max duration is set to 90 mins you need to change it to at least as long as your schedule if you want it to heat for...
The only suggestion I have is there is an eco and std setting for HW heating, if it’s on eco change it to std it will make the HP worker harder for t...
So is a pump running constantly that is linked to the Heatmiser? if so, set it to be off when the hot water is heating see if that makes a differenc...
So it will only run for 90 mins before shutting off and that currently isn’t long enough to reach your set temp In the HW schedule on the FTC when i...
@ngillam that all looks normal it’s just defrosting
What does this mean do you have hot water being pumped round a circuit?
check what the HW pump is set to on the cylinder it should have 3 positions it should be on 3 which is the highest setting
@rhh2348 There are 3 adjustments in the compensation curve menu, the left one adjusts where the colder OAT flow temps start, the middle one adjusts w...
Flow and return are fine, what isn't is the rate at which it is changing. If I look at my HW run last night to get from 37C to 42C flow mine took 5 ...
@grumpidoc I would still go into the menu when its running and check what the pump speed is set to and what the flow rate is, then you will have that ...
@ngillam No way to control defrost cycle, but that isn't your issue it only increased 5C in 30 mins before the defrost started that isn't normal, its ...
@ngillam Mine performed the same as normal hw took an hour to get to temp which is typical, hw shouldn't struggle to get to temp so something isn't...
- 23 Forums
- 2,098 Topics
- 46.2 K Posts
- 35 Online
- 3,385 Members
Join Us!
Latest Posts
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 7 minutes ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 10 minutes ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 7 hours ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
Hmm Before doing that I would want to be certain that...
By JamesPa , 12 hours ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 12 hours ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 23 hours ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 1 day ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 1 day ago
-
If you are thinking of heating on the immersion conside...
By JamesPa , 3 days ago
-
RE: Surface mount or bury primaries for heat pump installation?
@tomasmcguinness, I think your best bet would be using ...
By Aventus Eco , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles all depends on asking the right questions! And...
By Tim441 , 3 days ago
-
RE: Commencing on an ASHP Installation Process
I received confirmation this morning that my Greener Ho...
By Sheriff Fatman , 3 days ago
-
@jamespa Thanks for the advice - very helpful. I had al...
By abam48 , 4 days ago
-
RE: Adding battery storage to SolarEdge PV system
@chandykris No need to apologise at all! I forgot to ad...
By Toodles , 5 days ago