Last seen: Jul 24, 2025
As I said in a previous post your max duration is set to 90 mins you need to change it to at least as long as your schedule if you want it to heat for...
The only suggestion I have is there is an eco and std setting for HW heating, if it’s on eco change it to std it will make the HP worker harder for t...
So is a pump running constantly that is linked to the Heatmiser? if so, set it to be off when the hot water is heating see if that makes a differenc...
So it will only run for 90 mins before shutting off and that currently isn’t long enough to reach your set temp In the HW schedule on the FTC when i...
@ngillam that all looks normal it’s just defrosting
What does this mean do you have hot water being pumped round a circuit?
check what the HW pump is set to on the cylinder it should have 3 positions it should be on 3 which is the highest setting
@rhh2348 There are 3 adjustments in the compensation curve menu, the left one adjusts where the colder OAT flow temps start, the middle one adjusts w...
Flow and return are fine, what isn't is the rate at which it is changing. If I look at my HW run last night to get from 37C to 42C flow mine took 5 ...
@grumpidoc I would still go into the menu when its running and check what the pump speed is set to and what the flow rate is, then you will have that ...
@ngillam No way to control defrost cycle, but that isn't your issue it only increased 5C in 30 mins before the defrost started that isn't normal, its ...
@ngillam Mine performed the same as normal hw took an hour to get to temp which is typical, hw shouldn't struggle to get to temp so something isn't...
- 26 Forums
- 2,114 Topics
- 46.4 K Posts
- 118 Online
- 3,410 Members
Join Us!
Latest Posts
-
@eliuccio good to hear you’re happy with the install. A...
By Mars , 2 hours ago
-
RE: No-code, plug-and-play monitoring for your heat pump
The issue with the Grant is that you have to wire direc...
By Grantmethestrength , 18 hours ago
-
RE: Is this just haze or something more?
I am not a scientist nor a meteorologist and I know the...
By Toodles , 18 hours ago
-
RE: Benefits of an extra horizontal loop for GSHP
It will improve performance, but by how much depends on...
By Brendon Uys , 22 hours ago
-
RE: The good, the bad and the not that great – my heat pump installation
Said I would pop back with a update. Only Mr Jesus h...
By Burtis , 2 days ago
-
RE: Buffers, hot water and cooling
Thats presumably heat pump DT, what about radiator DT a...
By JamesPa , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Exactly the same here. We now have 13.5kWh ...
By Old_Scientist , 2 days ago
-
Compressor and Evaporator Stratification
I have had a few issues with my Hitachi spilt heatpump ...
By trebor12345 , 2 days ago
-
RE: Wood burner with ASHP - direct air?
This depends on the size of your wood burner and size/t...
By Lucia , 3 days ago
-
RE: Difficult positioning of air source heat pump
@rikiarn It's a not a buffer it's a volumiser which is ...
By Lucia , 3 days ago
-
RE: Is your heat pump insured?
To make things clear, lots of insurance companies cover...
By Lucia , 3 days ago
-
RE: Boxt Heat Pump Installation Experience
@adrian any updates since installation? How is it perfo...
By Ashfp , 3 days ago
-
RE: Say hello and introduce yourself
Hi @seatonian - Yes, I know Seaton, and I have the Nat...
By Transparent , 4 days ago
-
@seatonian got your email. Will connect you with a reco...
By Mars , 5 days ago
-
@downfield and @toddles, this isn’t in the settings cur...
By Mars , 7 days ago
-
RE: Homely launched for Grant Aerona ASHP control
I haven't bought the Aerona Smart Controller (£700!) bu...
By Prunus , 7 days ago
-
RE: Antifreeze top up for my heat pump - is this a rip off?
For the record, Grant supply ethylene glycol for their ...
By Prunus , 7 days ago
-
RE: Compressor attempts start but fails - Nibe Fighter 2005 8kW
@skyefarmer amazing. Well done!
By Mars , 1 week ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Ebac 5kw - Monobloc R32. Developed and made in UK - Mit...
By marcinwloch69@gmail.com , 1 week ago
-
RE: Is a Valliant Inline 6kW heater a BUS buster?
Just another thought - it might be worth thinking about...
By JamesPa , 1 week ago