Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Craig1980
@craig1980
Member
Estimable Member
Joined: Nov 23, 2022
Last seen: Mar 2, 2025
Topics: 5 / Replies: 141
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@derek-m the 405 # settings. Probably 4052 to get my flow and return temps to have a larger difference or have I misunderstood the job of these settin...

3 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@derek-m so would these actually make any difference to the difference in flow in and out temps if I adjusted them? I'm getting between 3 & 4 degr...

3 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@mike-h I have one on the in and one on the out. I adjusted both. I haven't tried just one.

3 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@derek-m I've found a setting under heat #40** #405* has an option #4052 that sets the inverter pump to run to adjust delta t. Is this a setting ...

3 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@derek-m I have set the pump to speed 2 of 3 so medium speed. I now have a flow rate of 24 l/pm. From what I understand this is the minimum it should ...

3 years ago
Reply
RE: 12kW Samsung gen 6 short cycling

@derek-m that is entirely possible. Would also explain the misuse of the description "indoor unit".

3 years ago
Reply
RE: 12kW Samsung gen 6 short cycling

I'm on value 2 that says pump 1. I used this YouTube clip to get away from WC. There is probably an easier/better way but this way served it's p...

3 years ago
Reply
RE: 12kW Samsung gen 6 short cycling

I was on what I believe is value #4. The one that says pump 3. This was giving the affect of short cycling. I'm listening by the UVC not the outside u...

3 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@derek-m okay, I'll do that later today. Thanks

3 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@derek-m yeah, I'd realised that. Unfortunately my bladder is strong enough to last through the night so I don't need to get up in the early hours yet...

3 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@derek-m thanks again. I assume that is done with the button on the pump itself? I also assume that I should adjust both to the same?

3 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@kev-m yeah, I don't have a programmable temp set back either but quiet mode runs at less power. I can't really find any information on it though othe...

3 years ago