Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 31, 2026
@davidb Im not aware that you need a smart meter to have a home battery David.
Your COP is pretty decent so you will probably be looking at fine tuning and or system changes which might be expensive. If your flow temperature is...
This may be totally unrelated to your problem but I was observing a similar saw tooth plot on a Mitsu with Melpump. The issue was caused by...
@papahuhu I understand that quite common for them not to make clear the minimum output. I think 30-35% of the badged output is about average
@papahuhu Well its certainly not helping! What is its minimum output at various flow temps. That should give you a clue. Oversizing of heat pumps is r...
@papahuhu Its really tricky to get these things remedied. Good luck. For interest how big is your heat pump and your house?
@toodles Glad you got your money back Toodles. Unfortunately I didnt buy my wind farm shares with a CC 🤣
@papahuhu Hope you get somewhere with them. Sounds like you know what the problem is. Did you pay by credit card? If you cant get anywhere, it might...
@papahuhu OK, filled cavity and 300mm insulation would sound about right. I think you are correct and they missed the fact that the attic insulation i...
@papahuhu Im struggling to understand why they took a bigger radiator out? What type of construction is your house? when was it built? At 28 W/m2 Im g...
@papahuhu That may be telling. Measure your radiators. Take a photo and measure the room its in. Let me know roughly its date of construction and we s...
@papahuhu I would concentrate on the upstairs radiators. If the downstairs rooms are warm then there is enough heat when the emitters are working prop...
- 27 Forums
- 2,781 Topics
- 65.6 K Posts
- 2,672 Online
- 7,187 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Tesla Powerwall (2) Calibration Cycles
@toodles when you mentioned there had been an improveme...
By Papahuhu , 39 minutes ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
That sounds like a better approach (being able to see a...
By cathodeRay , 19 hours ago
-
RE: DIY Heat Pump Installations: Navigating Legal and Regulatory Hurdles
Thanks for the reference @jamespa I can't see any te...
By Transparent , 21 hours ago
-
RE: battery storage without solar
Indeed, current on the grid input = current used for ch...
By bobflux , 21 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu @papahuhu A lot of tears and sweat went into ...
By Andris , 1 day ago
-
RE: Getting closer to a finished Haier system
Very nice! Congratulations. Big MLC looks neat whe...
By bobflux , 1 day ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
We have the same problem, 12 mature trees clip the morn...
By Papahuhu , 2 days ago
-
RE: Solis inverters S6-EH1P: pros and cons and battery options
I had a battery and inverter installed a while ago, my ...
By Batpred , 2 days ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
@ltron2 The EPC on our house is A-92, however that i...
By Rob of York , 2 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
The layout is confusing - much better like this: We b...
By downfield , 3 days ago
-
RE: Is it just me, or does tradesperson timekeeping and communication drive you absolutely mad?
My experience, backed up by opinions from various frien...
By Majordennisbloodnok , 3 days ago
-
RE: Analysis of the economics of switching to an A2W ASHP compared to other heat sources
I had a meeting today with a company based out of Swede...
By Mars , 4 days ago
-
RE: Review your electricity provider
We were with Octopus in our old house and it was fault...
By ian33a , 4 days ago
-
RE: Estimating true heat loss from twelve months of consumption data
I did, indeed, go with the 12 KW Vaillant unit.  ...
By ian33a , 4 days ago