Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 3, 2025
@prjohn thank you. That's 214 w/m2. As a note we were 244 w/m2, so about 10% higher than yourself in terms of heat demand per m2. I'm sure there a r...
@prjohn what's your floor space area you are heating? Would be good to understand your w/m2 to put the 24kW figure into context
64kW used and 184kW delivered yesterday in total for CH. COP 2.55 w/m2 244
@editor shading is killing me at the moment. Must be costing me 20kW a day, minimum
@editor if it makes you feel better, we've used about 80kw today with heating, hot water and general life - so you avoided all of that
@kev-m we are now at 49kW used and the average ambient has dropped to 4° Heat delivered 145kW COP: 2.95
@derek-m I think the sensors are integral. The only external sensor is in the hot water tank. Perhaps @grahamh can help. He seems to be the man who kn...
@derek-m as ever I'm always appreciative of the knowledge on this forum. All I was trying to say is that all models are built on a range of assumption...
@hr_3 depends on the rooms. 5 everywhere and then adjust the bedrooms as needed.
@keithh it didn't come up. However our upstairs is crazy in terms of insulation. It's 300mm solid between the walls, then 50mm on the outside plus 400...
@hr_3 do you know your current heating use in kW? You can just divide this by the total area of your house and that's your w/m2. However this will var...
@derek-m yes but that data came from the manufacturer about their performance based on lab testing. I can imagine in the real world the system is simp...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 2,494 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
@penval, really useful update. After all the discussion...
By Mars , 1 hour ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 22 hours ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 1 day ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 1 day ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 1 day ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 1 day ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 2 days ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 2 days ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 3 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 3 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 4 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 4 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 4 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 5 days ago