Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 18, 2026
@netdonkey Hey Net, keep bleeding the air, there can be no air, not even a smidge, any air will reduce the circuit performance, Samsung are sensitive ...
did it arrive like that as I can see banding around it or was it in a box and someone has un-packet it and discovered the coil fin damage?
@athlonoc Its unlikely the FTC is controlling a 3rd party pump (Wilo) so thats just on the pump control, you will need to run this system at least 15l...
@sorin I don't know if having the cooling enabled would invalidate the energy delivered, I would have thought that would read regardless of the functi...
Call MItsi Tech and they will walk you all the way through it. 01618666089 You need heating option from what I remember.
@david999 Ah, I kind of agree with a lot of what you are saying, I cant comment on the heat geek scheme as I dont know it well but from what I could s...
@editor (South East Costs vary - £175 to £300) for a full system service the reason the costs is twice a boiler is because it should take twice as lo...
If any of the main circuit is smaller than 28mm F/R you will get a fair bit of noise above 15 l/m, once the circuit has dropped off to a couple of emi...
@netdonkey excellent, I am glad I was thinking down the right track from the beginning, well done, the system really needs more flow than that, I woul...
@netdonkey yes you would have one in the condenser but its inside the cover and it would look something like that attached link. In your picture wh...
@netdonkey Sorry, one more thing, I note you say the system was installed in June 2024? if so, you are still well within your warranty and under HIES ...
@netdonkey I think if what you did just now made the system run for longer then it is air in the system and your flow may now have improved. As with...
- 27 Forums
- 2,800 Topics
- 66.2 K Posts
- 3,330 Online
- 7,206 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: New Build 3 Phase or 1Phase
Posted by: @e-a-west Ideally I would prefer a compl...
By Rob of York , 1 hour ago
-
RE: How will removing the standing charge on gas bills benefit heat pumps?
I think it has an enormous impact on air/air users. The...
By EtchedPixels , 5 hours ago
-
@editor Ouch, sorry to re start the tick. I had assume...
By DavidB , 22 hours ago
-
RE: Say hello and introduce yourself
@e-a-west as the good Major said, welcome to the forums...
By Mars , 23 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
Yes I actually have a copy of a tool that whenever a ce...
By EtchedPixels , 1 day ago
-
RE: Indevolt Batteries UK Support & Info Thread
@editor Hi, To resolve this, please tap on the A...
By Indevolt Tech , 2 days ago
-
RE: Double or Triple Glazed Windows?
Posted by: @singlespeed With 9 years repairing windo...
By Rob of York , 2 days ago
-
@transparent we’re still running a secure version of PH...
By Mars , 2 days ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
Much longer than that here. The heating isn't even on. ...
By bobflux , 3 days ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
Obviously the weather is changeable but there's a defin...
By Singlespeed , 3 days ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@rob-of-york I must admit that when we had a Daikin hea...
By Toodles , 3 days ago
-
RE: Forum updates, announcements & issues
Get the Renewable Heating Hub heads-up on WhatsApp. I...
By Mars , 3 days ago
-
RE: Safety study for plug in batteries out to tender - looks like Q3 2027 at best before legal
@editor I pointed out to the one of the Fuse execs that...
By dansus , 3 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews As well as loft insulation, there are othe...
By Rob of York , 3 days ago