Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

ASHP-BOBBA
@ashp-bobba
Member Professional+
Prominent Member
Joined: Dec 6, 2024
Last seen: Aug 4, 2026
Topics: 2 / Replies: 491
Reply
RE: Samsung E911 intermittent issue

@netdonkey ah so it was working last winter then?

2 years ago
Reply
RE: Samsung E911 intermittent issue

@netdonkey is this system only 6 month old? If you you are well within your warranty and if it is not working they should attend and repair? I woul...

2 years ago
Reply
RE: Samsung E911 intermittent issue

@transparent also the circuit might work enough on DHW alone and was not set up for heating if this is the 1st winter?

2 years ago
Reply
RE: Samsung E911 intermittent issue

@netdonkey Hey Net, keep bleeding the air, there can be no air, not even a smidge, any air will reduce the circuit performance, Samsung are sensitive ...

2 years ago
Reply
RE: Samsung heat pump has arrived with damaged fins – do I accept it or send it back?

did it arrive like that as I can see banding around it or was it in a box and someone has un-packet it and discovered the coil fin damage?

2 years ago
Reply
RE: Noise Issues with our Ecodan 8.5kW WM85VAA air source heat pump

@athlonoc Its unlikely the FTC is controlling a 3rd party pump (Wilo) so thats just on the pump control, you will need to run this system at least 15l...

2 years ago
Reply
RE: Mitsubishi Ecodan Produced energy showing 'INVALID'

@sorin I don't know if having the cooling enabled would invalidate the energy delivered, I would have thought that would read regardless of the functi...

2 years ago
Reply
RE: Mitsubishi Ecodan Produced energy showing 'INVALID'

Call MItsi Tech and they will walk you all the way through it. 01618666089 You need heating option from what I remember.

2 years ago
Reply
RE: Questions and comments about annual heat pump maintenance and servicing

@david999 Ah, I kind of agree with a lot of what you are saying, I cant comment on the heat geek scheme as I dont know it well but from what I could s...

2 years ago
Reply
RE: Questions and comments about annual heat pump maintenance and servicing

@editor (South East Costs vary - £175 to £300) for a full system service the reason the costs is twice a boiler is because it should take twice as lo...

2 years ago
Reply
RE: Noise Issues with our Ecodan 8.5kW WM85VAA air source heat pump

If any of the main circuit is smaller than 28mm F/R you will get a fair bit of noise above 15 l/m, once the circuit has dropped off to a couple of emi...

2 years ago