Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

ASHP-BOBBA
@ashp-bobba
Member Professional+
Prominent Member
Joined: Dec 6, 2024
Last seen: Jun 15, 2026
Topics: 2 / Replies: 480
Reply
RE: First time wall mounting an ASHP

what you need to do is everything you can to remove the vibration through the wall, these brackets are very good and allow you to adjust a rear foot t...

7 months ago
Reply
RE: Daikin Short Cycle Query

@treewizard is this not the electrical pulse that keeps the compressor warm? most of these top end builds use around 1kW per day in the winter to eith...

7 months ago
Reply
RE: UFH downstairs and radiators upstairs balancing question

@davidnolan22 Hi, ok first of all it very hard to truly balance duel UFH circuits and rads when they have a shunt, Splan valve and a manifold pumps, u...

7 months ago
Reply
RE: UFH downstairs and radiators upstairs balancing question

@walnut-tree-cottage So you have no stats on any of the UFH and its fully open loop? if this is the case you need to make sure the Rads are DT5 and th...

7 months ago
Reply
RE: UFH downstairs and radiators upstairs balancing question

@walnut-tree-cottage My bad, sorry I transpose while trying to do 3 things at once, so its worth measuring what the DT is on the radiators to see how ...

7 months ago
Reply
RE: UFH downstairs and radiators upstairs balancing question

@walnut-tree-cottage - Pop all the heads off the UFH rail, wind the balancing valves all the way down to close, DT measure the rad in the hall to 4DT ...

7 months ago
Reply
RE: New build installation query

@paullacey While the others wait for more info do you mind if I ask a couple of questions and see if I can also help? Did I read correctly that the...

7 months ago
Reply
RE: Faulty Clivet heat pump out of the box

We would never win these projects as we spend 1 whole day all day at the end of every job IR camera every pipe and rad, DT measure and data log every ...

8 months ago
Reply
RE: Ecodan Melcloud Temperature Change

@gruff2001 - if set on WC, the app is only communicating to the controller and reading the stat against the weather curve, there are so many settings ...

8 months ago
Reply
RE: Mitsu PAR-WT60 Wireless Controller

Aslo, subject to FTC version, Your thermostat will control your home dynamically, here is a short video explaining

8 months ago
Reply
RE: Mitsu PAR-WT60 Wireless Controller

If dip switched correctly and wired correctly and subject to what programme was issues it will 1st for 15mins force the ASHP to rapidly heat the water...

8 months ago
Reply
RE: Mitsu PAR-WT60 Wireless Controller

@davidalgarve press and hold for a few seconds and it should push the system into a boost hot water mode, tap symbol will be on the screen in a steady...

8 months ago