Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

AllyFish
@allyfish
Contributor
Prominent Member
Joined: Oct 31, 2022
Last seen: Mar 16, 2026
Topics: 23 / Replies: 494
Reply
RE: Watch Where Your Installer Fits Motorised Valves

@editor I see. I knew there would be sound reasons. My ASHP is barely big enough, and I've seen aveage room temperatures drop a couple of degrees over...

1 year ago
Reply
RE: Grant ASHP - flow temp on display often nonsensical

Hi @crimson, I think field 2 is compressor discharge temperature, field 0 is return water temp, 9 is leaving water temp. Check the Grant installation ...

1 year ago
Reply
RE: Maximising Savings: Navigating My First Year with Octopus Energy and Heat Pump Running Costs

Yes, this! Thermal mass is key. Ancient civilisations knew a thing or two about using solar reflecting lighter buildings, natural ventilation for cool...

1 year ago
Reply
RE: ASHP + UFH, no circulation pump

@pie_eater I don't know the Daikin Madoka product, but having had a quick look on-line, it seems it's a simple binary [digital on/off] thermostat comp...

1 year ago
Reply
RE: Grant Aerona Cutting Out. Hot Water fine.

Great to know you've made good progress @martyj76, and ruled the pump out. The two port valve could well be faulty, it might be a fault with the valve...

1 year ago
Reply
RE: ASHP + UFH, no circulation pump

@pie_eater different manufacturers have differing accuracies of COP data, some are just considering the refrigeration compressor, some are total unit ...

1 year ago
Reply
RE: ASHP + UFH, no circulation pump

Beware the OEM COP 'vanity data' - most if not all heat pump controllers give very flattering [for flattering read exaggerated] COP data. True measure...

1 year ago
Reply
RE: Bad COP? Long Pipe Run on Cosy6 Saga Continues.

With the ASHP installed in a neighbouring street it's going to struggle with heat loss & hydraulic resistance. Clearly no-one had done any proper ...

1 year ago
Reply
RE: Is the Grant controller a thermostat?

Hi there @bajj, you've cracked it I think with setting parameter 21 41 to 2degC. UFH will have a very slow hysteresis response as the mass of the floo...

1 year ago
Reply
RE: Grant Aerona Cutting Out. Hot Water fine.

This is strange @martyj76, if the unit was installed by a Grant G1 installer, and has been annually serviced by a Grant G1 service engineer, it will b...

1 year ago