Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 15, 2025
Agreed, but as we are looking at something that's set to run 24/7 then the other featured don't need to be changed / looked at. So if does decide to t...
Nice looking controller, follows much the same as other ones. Would need to see some documentation about advanced mode, as ideal could be setting up t...
@jamespa I don't think any system, without lots of hardware will be able to balance emmitters. That will always be done by hand etc. Yes Homely c...
As I've stated before a good add on controller, working with IAT and adjusting flow temp, will cover nearly all the problems we have encountered. Al...
I would say your heat loss for the house is about right. I take it at 5kw, but never bothered to work it out myself, and that would fall into the righ...
@ajbevster Okay, I think I understand now, but might not have it all correct. The Glenhill has its own internal 70l buffer and 300l cylinder and the...
Cheers, I think the 72l one can be ignored, could be there as a volumizer and shouldn't effect flow/return. Is the Gledhill your DHW system ? Not...
Normally I don't like asking lots of questions, but here we may need some more information - Do you have a buffer/low loss header or volumizer in th...
@transparent Glad I could help, without realising it. Going for a tea and a read of your guide.
Thank you, yes we have MVHR system. That's what I have been saying and hence the reason we run it the way we do. I've since learned not to criti...
@heatgeek It's very much passive house and at 538m², with 1300kwh heating (as taken from a meter just for the HP). That works out at less than 2.5...
@heatgeek Thank you, yes this is quite a meal and I'll try to understand each part. --- "efficiently use such a large HP to directly heat yo...
- 27 Forums
- 2,811 Topics
- 66.5 K Posts
- 1,855 Online
- 7,217 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@susannasaunders And yes, an A2W system just doesn...
By Rob of York , 3 minutes ago
-
RE: Why don't people choose heat pumps?
It's swings and roundabouts - during off-peak periods t...
By Temperature_Gradient , 53 minutes ago
-
RE: Adding data centre electricity costs to domestic energy bills?
never ceases to amaze me.. Keeping steel works going ...
By Batpred , 8 hours ago
-
RE: Electricity price predictions
great session Reminds me why some politicians can be ha...
By Batpred , 8 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Absolutely agree. The massive Hager CU my vaillant requ...
By Batpred , 8 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
absolutely agree. even if many providers see that extra...
By Batpred , 9 hours ago
-
RE: Octopussy cosy 6 experience
People who have a Cosy appear generally to be happy wit...
By JamesPa , 12 hours ago
-
I thought the cr*p came first and the biofuel came afte...
By Majordennisbloodnok , 16 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 2 days ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 4 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 4 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 4 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 5 days ago