Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 1, 2026
I have been writing down the temperatures on the probes on top of the buffer. High Point just prior to Defrost Cycle Two - 28.8C (significant drop...
Twi (Temperature Water In) is Hitachi's term for water returning to the Heat Exchanger. Remember, my temperature sensor are not metal probe...
This is the manifold. Zoom in to see actuators are removed.
The secondary pump runs all the time when there is a demand for heating and when in the Thermo Off situation. Yes the power cut turned the heat pump...
JamesPa. Data for the 26 November -4C OAT during night. 11C OAT during latter day. Water Temperature FIXED @ 31C. This temperature is a litt...
JamesPa I plan to send you a chart tomorrow of todays (26th) result. Just to make sure I am giving you what data you need.
I wish I had only 9 defrosts in that timeframe. I had 16 in the early morning of just the 26 Nov.
Sim0n0. I also have the Hitachi Yutaki system. Also having lots of problems.
Thank you for the reply. I think you are saying that what I am seeing is normal (Evaporator -23C. OAT -4C. Defrost cycle every 46 minutes).  ...
You could be right in that it's a region between the 2 dotted lines. It's not clear to me what the chart really means, not my area of knowledge. May...
Concerned about the noise and build up of ice. I believe that the evaporator should not be getting down to -23C, based on the algorithm. If I am inte...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,865 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
@penval, really useful update. After all the discussion...
By Mars , 3 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 1 day ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 1 day ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 1 day ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 1 day ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 1 day ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 2 days ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 2 days ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 3 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 3 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 4 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 4 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 4 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 5 days ago