Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 9, 2026
@chansug An increase in that loft insulation would be a good investment too. You may be able to get a grant from your local authority to cover the cos...
@cressie I have noticed a trend in the last year or so; the attitude seems to be towards having a battery - even in preference to solar PV if the budg...
@alfapat Sounds to me as though we require an Ombudsman solely to deal with heating installations.😒 Toodles.
@clockworks And it would appear that they can control some other (non-Cosy) heat pumps too. They appear to be able to work with Daikin; this may be be...
Perhaps for clarity, I should mention that I used the term ‘Energy UK’ in my email to OE; I used it as a generic term for the generation and distribut...
@clockworks Regarding the Cosy tariff and heat pumps, here are a couple of extracts from recent communications I have had from O.E. “Thank you f...
@clockworks It rather sounds as though the heat pump manufacturers (or rather their software programmers) are not taking on board the need to lessen s...
@clockworks Sounds like you may have your answer there then! Regards, Toodles.
Possibly a dodgy immersion heater thermostat? An immersion heater element would normally run (the 3 kW power level is right) until it reaches the set ...
@cathoderay May I suggest a slowly-slowly approach? Start by shutting just one or two of the LSV’s in stages; these should be the ones in rooms that a...
@alfapat In that RHH Q&A presentation, there was mention of compatibility with Homely and / or Havenwise controllers and monitors; the advice seem...
@cathoderay Perhaps you need to adopt a ‘Paddington Stare’! 😉
- 26 Forums
- 2,622 Topics
- 61.2 K Posts
- 1,220 Online
- 7,003 Members
Join Us!
Worth Watching
Latest Posts
-
-
RE: GSHP Kaput After 16 Years: New Compressor or Switch to ASHP? Advice Welcome
On old (non inverter) compressors there’s sometimes a ‘...
By robl , 16 hours ago
-
RE: Brown Oily Residue Blocking Air Vent and Weeping Relief Valve... Anyone Seen This?
I'll take a photo of it if and when I next encounter it...
By seoras , 19 hours ago
-
RE: Heat Pump Pipe Sizing Question
@trebor12345rebor12345 I got the circulator curves from...
By bobflux , 23 hours ago
-
RE: Jokes and fun posts about heat pumps and renewables
That particular Tracking system gets updated as soon as...
By Transparent , 1 day ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@editor It's available here -
By HarrisonC , 2 days ago
-
@painter26 i am in Lightwater and midea trained. Sounds...
By Wizard , 2 days ago
-
RE: Renewables & Heat Pumps in the News
@jamespa, for all I know they did have the coupling and...
By Mars , 2 days ago
-
@andrewj ... well, clearing gutters is a worthwhile ann...
By colinc , 2 days ago
-
RE: Anyone concerned about GivEnergy?
Here is the latest communication from GivEnergy regardi...
By txmartyn , 2 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
Can @editor please clarify: Does the Indevolt App com...
By Transparent , 2 days ago
-
@editor I too had a long list of questions, some of ...
By Bash , 2 days ago
-
RE: Tell us about your Solar (PV) setup
3.84kWp of solar on our main South-East facing roof, in...
By Gmuzz , 2 days ago
-
RE: Mitsubishi Ecodan FTC6, Evohome & Economy 7. Getting Two Zones to Work Together
Lets step back. Why do you need/want 2 zones? The hea...
By JamesPa , 2 days ago
-
RE: Vaillant arotherm plus heat pump frost protection
Yes, typically as close to the heat pump as possible. ...
By JamesPa , 2 days ago
-
RE: Our 10 year old Grant heat pump failed
Back in the 70’s and through the eighties, one of my re...
By Toodles , 3 days ago
-
RE: Share Your Experiences with Heat Pump Manufacturer Support
@seoras Sorry to hear that. I found Vaillant very help...
By JamesPa , 4 days ago
-
The Watchdog That Watched and Waited
On 9 January 2026, Consumer Energy Solutions collapsed ...
By Mars , 4 days ago
-
RE: Valliant Heat Pump Settings
Thats arguably a sign of a good installer - they unders...
By JamesPa , 4 days ago
-
RE: Electricity price predictions
Well, we have so many cases where rain water mixes with...
By Batpred , 4 days ago
-
RE: Two heating zones to one zone
@profzarkov They arent obviously wrong, but the only...
By JamesPa , 4 days ago
-
RE: Towns water feed to air source heat pump system
The DHW circuit cant be separated (well it could, you c...
By JamesPa , 4 days ago
-
Solis AC-coupled 3kW storage inverter
Solis AC-coupled 3kW storage inverterPylontech batterie...
By MartinRobinson , 4 days ago
-
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer
As @transparent has observed above, this is not bad, an...
By cathodeRay , 4 days ago


